Installation
5
Installation
5.1
Unpacking
Check the product for damage while unpacking. In the event of damage to the
product, inform the post office or parcel service and notify the supplier.
Check the package contents with your purchase order and the shipping
documents for:
■
Delivery quantity
■
Device type and version in accordance with the type plate
■
Accessories
■
Quick start guide
Retain the original packaging in case you have to store or ship the device again at
a later date.
Should you have any questions, please contact Fuchs.
5.2
EMC concept
The outstanding noise immunity of the IDENTControl Compact against emission
and immission is based on its consistent shielding design, which uses the
principle of the Faraday cage. Interference is caught in the shield and safely
diverted via the ground connections.
The screening of cables provides for the discharge of electromagnetic
interference. When screening a cable, both sides of the screen must be
connected to the earth with low resistance and low inductance.
The metal enclosure of the IDENTControl Compact and the metal enclosure of the
R/W heads complete the consistent shielding concept.
Read head
PLC
IDENTControl
PROFIBUS
Note!
If cables with double shields are used, e.g. wire mesh and metalized foil, the both
shields must be connected together, with low resistance, at the ends when
making up the cable.
Power supply cables are the source of much interference, e.g. from the supply
lines of 3-phase electric motors. For this reason, the parallel laying of power
supply cables with data and signal cables should be avoided, particularly in the
same cable duct.