Technical specifications
20
13-
01
83
8
Technical specifications
8.1
Dimensions
8.2
Technical data
General specifications
Indicators/operating means
Electrical specifications
33
42
136.6
61.4
36
15
107
CH2C
H
2
CH1C
H
1
Number of read/write
heads
max. 2
alternatively 1 read/write head and 1 trigger sensor
LED BUS
green: Slave is at state Data Exchange
red: Bus error
LED Diag
No function
LEDs 1, 2
Status indicator for read/write heads
green: command at read/write head active
yellow: approx. 1 second long, if command was successfully
executed
LEDs CH1, CH2
green: read head detected
red: Configuration error
LED PWR/ERR
green: power on
red: Hardware fault
Rotary switch
Address setting 00 ... 7E, FF (hexadecimal)
BUS Address (high nibble): 0 ... 7, F
BUS Address (low nibble): 0 ... F
Rated operating voltage
20 ... 30 V DC , PELV
Ripple
10 % at 30 V DC
Current consumption
4 A incl. read/write heads