![Pentatech 3000 Set F3 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/pentatech/3000-set-f3/3000-set-f3_user-manual_1526128027.webp)
26
screw hole
27
screw
28
bracket
29
fixing hole
30
wall plate
31
ball joint
32
screw
33
wall plug
34
battery compartment
35
LED jumper
36 ZONE jumper
37
sensor
38
LED
39
arrow marks
40
magnet
41
adhesive pad
42
ZONE jumper
43
battery compartment
Operating voltage
12 V DC (mains adapter)
Current consumption
max. 200 mA
Wireless frequency
433 MHz
Wireless components
max. 5 remote controls und max. 20
detectors enrollable
Sound pressure level
approx. 100 dB(A) / 1 m
Operating temperature
±0° C to + 40° C
Operating voltage
3 V DC
Current consumption
max. 10 mA
Power supply
2x 1,5 V AA alkaline batteries (LR6)
Wireless frequency
433 MHz
Wireless range
max. 30 m (in free space)
Detection area
approx 8 m through 110°
Operating temperature
±0° C to + 40° C
Operating voltage
1,5 V DC
Current consumption
max. 40 mA
Power supply
1x 1,5 V AA alkaline battery (LR6)
Wireless frequency
433 MHz
Wireless range
max. 30 m (in free space)
Operating temperature
±0° C to + 40° C
Operating voltage
3 V DC
Door/window contact 3000M (see Fig. E)
Siren 3000IS
PIR-detector 3000P
Door/window contact 3000M
Remote control 3000R
5. Technical data
Current consumption
max. 70 mA
Power supply
1x 3 V CR2025
Wireless frequency
433 MHz
Wireless range
max. 30 m (in free space)
Operating temperature
-10° C to + 40° C
Input voltage
230 V ~ 50 Hz
Output voltage
12 V DC , 500 mA
The following instructions are provided for your safety and satisfaction during
operation of the product. Note that non-observance of these safety
instructions results in significant risks of accident.
If this point is not heeded, life and health are endangered.
Do not leave small children unsupervised with the product, packaging
material or small parts. Otherwise there is a risk of fatal injury due to
choking!
Ensure that the alarm siren is not activated when persons are close to the
siren. Wear ear protection when testing the unit, otherwise there is a
danger of hearing damage.
Do not damage any gas, electricity, water or telecommunication lines
during drilling and fixing work. Otherwise there are dangers of personal
and fatal injury!
Treat the supply lines carefully. Lay these so that they cannot be
damaged and do not present any tripping hazard. Fix the cables
sufficiently. Do not pull the cables over sharp edges and do not crush or
crimp them elsewhere. Otherwise there are dangers of personal and
fatal injury!
Use only the supplied mains adapter with the siren. Before connecting
the power supply to the mains, ensure that the mains current complies
with 230 V ~, 50 Hz and is fitted with a fuse according to regulations.
Otherwise there are dangers of fire and fatal injury.
Do not allow the product to contact with moisture. Never immerse the
product in water. Otherwise there is danger of fatal injury!
Ensure that the batteries are not short circuited or exposed to fire. The
batteries must not be opened or recharged. Otherwise there is a risk of
fatal injury due to explosion!
Leaking or damaged batteries can cause burns by contact with skin.
Handle these using suitable protective gloves.
Non-observance of these instructions puts property at risk
of damage.
Before installing and operating the product check the package for
damages and completeness.
Do not connect any damaged device (e.g. transport damage) and
disconnect the power supply immediately in the case of damage.
Unplug the mains adapter from the mains socket. Arrange for the
damage to be repaired immediately by a specialist!
Mains adapter
Danger!
Attention!
6. Safety instructions
!
!
!
!
!
!
!
!
!
!
!
27