Page 17
Master Programming Mode
9. Feed Water Hardness (Display Code H)
This program step sets the feed water hardness. The letter H in the first digit of the display identifies this
program step. The system automatically calculates treated water capacity based on the feed water hardness
entered in this program step and the system capacity entered in program step #3.
Range = 1 – 199 grains/gallon (US [U - -1])
Range = 2 – 199 degrees (metric [U - - 4])
20 grains/gallon
Setting: [ H - 20]
— Use Set Up or Set Down buttons to adjust this value.
— Press the Extra Cycle button.
10. Regeneration Time (No Display Code)
This program step sets time of day for the regeneration to occur. A non-flashing colon between two sets
of numbers identifies the Regeneration Time display.
Range = Anytime
2 o’clock A.M. regeneration time
Setting: [ 2:00 ] (P.M. Indicator Off)
— Use Set Up or Set Down buttons to adjust this value.
— Press the Extra Cycle button.
11. Regeneration Day Override (Display Code A)
This program step sets the maximum amount of time (in days) the unit can be in service without a
regeneration. The letter A in the first digit of the display identifies this program step. For System Type
Time Clock Delayed [ 4tc ] the system regenerates at the time set in program step #5 after the number of
days programmed in this step. For any Meter System Types, the system regenerates after the number of
days programmed in this step at the same time of day that the previous regeneration occurred unless the
meter initiates a regeneration cycle earlier.
Range = 1 – 99 (Time Clock Delayed [ 4tc ])
Range = OFF, 1 – 99 (All Meter Regeneration Types)
Override every 14 days
Setting: [ A -14 ]
Option turned off
Setting: [ AOFF ]
— Use Set Up or Set Down buttons to adjust this value.
— Press the Extra Cycle button.
12. Regeneration Cycle Step Programming (Display Code 1 – 6)
This program step programs the Regeneration Cycle step times. Up to 6 Regeneration Cycle steps can be
programmed. The Regeneration Cycle Step being programmed is shown in the first digit of the display.
Each display sets the duration time in minutes of that specific step in the regeneration cycle. For regeneration
programs with less than 6 regeneration cycle steps, the time for the step # after the last active step must
be set to OFF. To skip a regeneration cycle step and go to the next cycle, the setting should be at 0. If
regeneration cycle step setting is OFF, the remaining cycle steps will not appear to set.
Range = OFF, 0 – 99 minutes (US [U - -1])
Range = OFF, 0 – 99 minutes (metric [U - - 4])
Regeneration Cycle Step #1 (10 minutes)
Setting: [1- 10]
Regeneration Cycle Step #4 (Cancel)
Setting: [4OFF]
— Use Set Up or Set Down buttons to adjust this value.
— Press the Extra Cycle button.
CAUTION: Before entering Master Programming, please contact your local professional water dealer.
Содержание Fleck 3200NT
Страница 1: ...3200NT Service Manual IMPORTANT Fill in Pertinent Information on Page 3 for Future Reference...
Страница 25: ...Page 25 Notes...
Страница 26: ...Page 26 Power Head Assembly 2750 2850 2900 Upper Drive and 2900 Lower Drive...
Страница 28: ...Page 28 Power Head Assembly 3150 3900 Upper Drive and 3900 Lower Drive...
Страница 36: ...Page 36 2750 2850 Timer Wiring Diagram...
Страница 37: ...Page 37 3150 Timer Wiring Diagram...
Страница 38: ...Page 38 2900 Timer Wiring Diagram...
Страница 39: ...Page 39 3900 Timer Wiring Diagram...
Страница 40: ...Page 40 3200NT Remote Timer Wiring Diagram 42073_REVA...
Страница 41: ...Page 41 2750 2850 3200NT Remote Wiring Diagram 42074_REVA...
Страница 42: ...Page 42 3150 3200NT Remote Wiring Diagram 42076_REVA...
Страница 43: ...Page 43 2900 3200NT Remote Wiring Diagram 42075_REVA...
Страница 44: ...Page 44 3900 3200NT Remote Wiring Diagram 42077_REVA...
Страница 49: ...Page 49 Notes...
Страница 50: ...Page 50 Notes...
Страница 51: ...Page 51 Notes...
Страница 52: ...P N 41093 Rev E 9 06...