EVERPURE

®

 CONSERV

®

 LT

-

S HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE

3.  Adjust the mixing valve if needed and run blended water 

for two (2) minutes. Discard this water.

4.  Repeat Steps 3, 4 and 5 until the light indicators change 

between solid blue and flashing blue. The blended water 

TDS should now be at 80 ppm.

10

 Install the Everpure

®

 4CC Mineral Cartridge:

Locate the 4CC Cartridge and inspect the o-rings. They 

should be clean and lightly lubricated with silicone grease.

1.  Turn power OFF.
2.  Remove the port plug.
3.  Line up the tabs on the 4CC Cartridge with the slots in 

the opening on the front side of the head assembly. See 

Figure 6 and insert the cartridge to full depth.

4.  Rotate the cartridge 90

0

 to the right (clockwise) to lock it 

in place.

1

2

4C

C

Figure 11 

11

 Flush Storage Tank and Everpure

®

 4CC Cartridge:

Flush the Everpure 4CC Mineral Cartridge:

The 4CC Mineral Cartridge will be flushed when the storage 

tank is flushed. No further flushing is required.

Storage Tank:

The Storage Tank will hold approximately 3 gals (11.3 L). The 

tank air pressure is preset to 5-7 psi (0.34 bar, 0.034 MPa) 

when shipped via ground transportation. For air shipments 

the precharge is completely removed. Check the tank air 

pressure. Ensure that the tank has 5-7 psi (0.34 bar, 0.034 

MPa) of precharge upon installation. Add air if needed. Tank 

pressure may be checked using an air pressure gauge on the 

air valve on the side of the tank.

Blended 

Water Outlet

Figure 12 

1.  OPEN the ball valve on the top of the Storage Tank.
2.  CLOSE the ball valve at the blended water out tubing.
3.  Apply power. It will take approximately two (2) hours for 

the Storage Tank to fill.

4.  The pump turns off when the Storage Tank is full. OPEN 

the ball valve for the blended water outlet. Allow the 

Storage Tank to empty.

5.  Repeat Steps 2, 3 and 4 four (4) more times.

PLACE THE CONSERV LT

-

S PROCESSOR INTO 

OPERATION

1.  Remove the ball valve from the end of the blended water 

outlet. 

2.  Connect the blended water outlet tubing to the 

application.

TESTING YOUR REVERSE OSMOSIS PROCESSOR

Total Dissolved Solids (TDS) Test

Under NSF/ANSI Standard 58, it is highly recommended that 

the blended water be tested at least every six (6) months to 

verify that the processor is performing satisfactorily.

CAUTION: Visually check the entire processor for leaks. If a 

leak is present, see Troubleshooting.

NOTE: Initially, the water may appear cloudy. This is a result 

of air trapped in the postfilter cartridge. It is not 

harmful and will disappear in a matter of minutes. 

It may take up to a week after installing a new 

postfilter cartridge for the trapped air to dissipate.

Содержание EVERPURE CONSERV LT-S

Страница 1: ...ounting the Conserv LT S Processor inspect the parts Use the table and illustration provided to verify the parts provided If any parts are missing contact Customer Service at 800 942 1153 US only 630 307 3000 or by email at CSeverpure pentair com Parts 1 Wall Unit with GRO 75EN RO Membrane Cartridge in Place 2 4CC Mineral Cartridge 3 4FC5 Filter Cartridge 4 Storage Tank 5 Parts Bag Containing Bypa...

Страница 2: ...s restricted to trained adult personnel No one should play with the appliance NOTE Children should be supervised to ensure that they do not play with the appliance NOTE Cleaning and user maintenance shall not be made by children without supervision NOTE The appliance is not suitable for installation in an area where a water jet could be used NOTE If the supply cord is damaged it must be replaced b...

Страница 3: ...d NOTE Substances listed as reduced are not necessarily in your water The Processor must be maintained according to manufacturer s instructions including replacement of filter cartridges NOTE Your water must be within required limits for satisfactory operation If not the RO membrane cartridge s life may be shortened and your warranty will be voided see Operating Specifications NOTE Install on cold...

Страница 4: ...4 WATER YOU CAN TRUST EVERPURE CONSERV LT S PROCESSOR 1 Secure Unit to Wall Approximately 25 lbs 11 3 kgs Operating Weight 1 3 2 Remove RO Membrane 2 3 ...

Страница 5: ...ge Tank 3 Connect Tubing for Flushing Precharge Storage Tank 5 7 psi 0 34 bar 0 034 MPa 3 8 Tubing Product Water Out 1 3 2 4 3 8 Tubing To Storage Tank 3 8 Tubing Supply Water In CLOSE OPEN 4 Prepare to Flush the Everpure 4FC5 Cartridge 1 3 2 Connect Electrical Install Bypass Plug CLOSE Unplugged Inlet Water ...

Страница 6: ...e 4FC5 Cartridge 1 2 4FC5 OPEN Plugged 1 4 Inlet Water Install Cartridge Flush to Drain Five 5 Minutes 2 3 5 Plug In Power Cord Unplug Power Cord Closed Valve As Shown 6 Prepare the Pentair GRO 75EN Cartridge for Use Replace Membrane 2 Remove Cover 1 ...

Страница 7: ...rtridge Storage Tank Not Shown 1 Remove Plug Push White 3 8 Tubing into White Connector 3 2 4 Push Red 3 8 Tubing into Red Connector Push Blue 3 8 Tubing into Blue Connector 8 Flush Pentair GRO 75EN Cartridge Plug In Power Cord Inlet Water Open Flush To Drain for 24 Hours 1 4 2 3 Fully CLOSE Turn To Right Unplug Power Cord ...

Страница 8: ...d Open 2 Solid Blue Blending Valve 1 4 Turn or Less 2 Solid Blue Blending Valve 1 4 Turn or Less 5 2 4 Repeat Until Flashing Blue Blending Valve 1 8 Turn Press Press 1 3 6 Plug In Power Cord Unplug In Power Cord OPEN One 1 Full CCW Turn of the Valve ...

Страница 9: ...9 EVERPURE CONSERV LT S HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE 10 Install Everpure 4CC Cartridge 1 2 4CC 1 Remove Port Plug 2 Install 4CC Cartridge ...

Страница 10: ...10 WATER YOU CAN TRUST 11 Flush Storage Tank and 4CC Cartridge 3 2 CLOSE OPEN 1 When Pump Turns Off OPEN valve 5 4 Plug In Power Cord Repeat Steps 2 and 4 Four 4 Times ...

Страница 11: ...more water the system is required to produce the longer the membrane will last INSTALLATION NOTE Please read all instructions specifications and precautions before installing and using your Conserv LT S Processor NOTE The Conserv LT S Processor may be installed hanging on a wall or set under a sink NOTE The Conserv LT S Processor must be installed vertically WARNING Improper connection of the appl...

Страница 12: ...er end to the Storage Tank and insert it into the ball valve The ball valve should be closed 5 Connect a length of 3 8 O D tubing to the Everpure Conserv LT S Processor outlet connection Secure an open ball valve to the other end and position it over a drain Water Supply Inlet Figure 3 4 Prepare to Flush the Everpure 4FC5 Cartridge The Everpure 4FC5 Filter Cartridge is installed and flushed before...

Страница 13: ... connect ports that are labeled Inlet White Product RO Water Blue Drain Red White Port Figure 7 CAUTION DO NOT remove the quick connect elbow fitting from the red tubing This assembly contains a flow control that may become damaged if removed The efficiency of the Everpure Conserv LT S Processor may be affected 1 Remove the GRO 75EN RO Membrane Cartridge from its packaging and position it with the...

Страница 14: ... depress blue cap Do not submerge entire unit 4 One 1 or two 2 lights will light immediately Match light s to the chart to get approximate range of Total Dissolved Solids TDS Release the blue cap and write down the TDS range 0 75 ppm solid blue 76 150 ppm flashing blue 100 250 ppm flashing blue solid green 251 300 ppm solid green 301 400 ppm flashing green 401 500 ppm solid green flashing green 50...

Страница 15: ...ck the tank air pressure Ensure that the tank has 5 7 psi 0 34 bar 0 034 MPa of precharge upon installation Add air if needed Tank pressure may be checked using an air pressure gauge on the air valve on the side of the tank Blended Water Outlet Figure 12 1 OPEN the ball valve on the top of the Storage Tank 2 CLOSE the ball valve at the blended water out tubing 3 Apply power It will take approximat...

Страница 16: ... access to the flow controller and the attached capillary tube Replace the flow controller Figure 13 in the red tubing 6 Insert a new flow controller Figure 13 with capillary tube into the tubing Replace the quick connect elbow Flow Controller Red Tubing White Tubing Blue Tubing Figure 13 7 Insert the new GRO 75EN RO Membrane Cartridge into position in the clip Rotate the cartridge so the quick co...

Страница 17: ...high quality silicone lubricant Replace the central plug assembly and insert the flushing cartridge into the left side head for the Everpure 4FC5 Cartridge NOTE Do not use petroleum jelly to lubricate the o rings It will degrade the o rings 2JT Plug 4CC Port Connect White and Blue Tubing Cartridge with Sanitizer Figure 15 6 Install a plug into the port for the 4CC Filter Cartridge NOTE A plug was ...

Страница 18: ... 3 Unscrew the tank valve from the storage tank 4 Inspect the rubber seal inside the threaded area Repair or replace the valve as needed 5 Thread the tank valve onto the top of the tank opening by turning it clockwise until snug 6 Wet the tubing and insert it 3 4 1 9 cm into the quick connect fitting 7 Turn water supply ON and CLOSE the application valve 8 Allow processor to pressurize for several...

Страница 19: ...nstallation must comply with state and local regulations Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts Substances that may be reduced are not necessarily in your water Filter must be maintained according to manufacturer s instructions including replacement of filter cartridges The efficiency rating for this system is 56 31 Efficiency ratin...

Страница 20: ...re technical service at the phone number listed below Any part found materially defective within the terms of this warranty will be repaired or replaced at PFS s discretion by your local dealer or Pentair Everpure technical service You pay only freight from our factory and local dealer charges Any item repaired or replaced pursuant to this warranty will be covered under the original warranty terms...

Отзывы: