background image

 11 

EVERPURE

®

 CONSERV

®

 LT

-

S HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE

HOW REVERSE OSMOSIS (RO) WORKS

The Everpure Conserv LT-S Processor uses a semi-

permeable membrane to reduce scale and corrosion. The RO 

membrane cartridge contains multiple layers of micron-thin 

film wound around a hollow center core. Water molecules can 

pass through the cartridge, while dissolved salts are rejected. 
Your water supply is prefiltered to reduce dirt and chlorine 

that may foul the membrane. The RO membrane cartridge 

separates this prefiltered water into RO WATER and REJECT 

WATER. Water pressure forces water through the membrane 

within the RO membrane cartridge then into the storage tank. 

This is the RO water. Dissolved salts cannot pass through the 

membrane and are sent to the drain as reject water.  
The Conserv LT-S Processor features a blend-in-tank process 

which uses the RO water described above, with calcium 

carbonate, and adds filtered water from carbon filtration to 

create a consistent product water. When you use water from 

the storage tank, the pressure inside the tank drops and the 

pressure switch closes. The system then begins to operate, 

replenishing the water you took from the storage tank. The 

storage tank can hold up to 3 gals (11.3 L) of water at one 

time.

NOTE: When used under operating conditions specified 

in this manual, the RO membrane cartridge of the 

Conserv LT-S Processor should last 12 to 24 months. 

The precise life span of the Pentair

®

 GRO-75EN RO 

Membrane Cartridge will depend on the quality of 

the water entering the system and the frequency 

with which you use it. Frequent use prevents the 

dissolved salts from building up on the membrane 

as scale. The more water the system is required to 

produce, the longer the membrane will last. 

INSTALLATION

NOTE: Please read all instructions, specifications, and 

precautions before installing and using your  

Conserv LT-S Processor.

NOTE: The Conserv LT-S Processor may be installed 

hanging on a wall or set under a sink.

NOTE: The Conserv LT-S Processor must be installed 

vertically.

WARNING: Improper connection of the appliance-

grounding conductor can result in a risk 

of electric shock. Check with a qualified 

electrician or service representative if 

you are in doubt as to whether or not 

the appliance is properly grounded. Do 

not modify the plug provided with the 

appliance; if it will not fit in the outlet, 

have a proper outlet installed by a 

qualified technician.

1

 Secure Manifold Wall Mount:

The Conserv LT-S Processor weighs approx. 25 lbs (11.3 kgs).

CAUTION: The Conserv LT-S Processor should be mounted 

on a stud or firm surface. The mounting bracket 

will support the weight of the system and help 

prevent strain on the water lines.

1.  Remove the Pentair GRO-75EN Membrane from the clip 

on the wall unit.

2.  When mounting the Conserv LT-S Processor on a wall, 

four (4) screws are required to mount the unit. The 

two (2) top screws will be 10.5" (26.7 cm) apart and 

level. Screw the two (2) screws into the wall. Leave a 

gap between the screw head and the wall of 1/8". The 

backside of the unit has two (2) slots that will fit over the 

screw heads and slide down to lock (Figure 2).

3.  Tighten both screws from the front.
4.  Insert screws into the two (2) remaining mounting holes. 

Screw them in and tighten.

 10.50”

(26.7 cm) 

 4x

 

0.45”

(1.1 cm) 

Mounting Screw Slots

Figure 2 

2

 Assemble Storage Tank:

1.  Locate the right angle ball valve. Screw the valve onto the 

top fitting of the Storage Tank until tight.

2.  CLOSE the ball valve.
3.  Apply precharge of 5-7 psi (0.34 bar, 0.034 MPa)
4.  Position the Storage Tank near the Conserv LT-S 

Processor. 

Содержание EVERPURE CONSERV LT-S

Страница 1: ...ounting the Conserv LT S Processor inspect the parts Use the table and illustration provided to verify the parts provided If any parts are missing contact Customer Service at 800 942 1153 US only 630 307 3000 or by email at CSeverpure pentair com Parts 1 Wall Unit with GRO 75EN RO Membrane Cartridge in Place 2 4CC Mineral Cartridge 3 4FC5 Filter Cartridge 4 Storage Tank 5 Parts Bag Containing Bypa...

Страница 2: ...s restricted to trained adult personnel No one should play with the appliance NOTE Children should be supervised to ensure that they do not play with the appliance NOTE Cleaning and user maintenance shall not be made by children without supervision NOTE The appliance is not suitable for installation in an area where a water jet could be used NOTE If the supply cord is damaged it must be replaced b...

Страница 3: ...d NOTE Substances listed as reduced are not necessarily in your water The Processor must be maintained according to manufacturer s instructions including replacement of filter cartridges NOTE Your water must be within required limits for satisfactory operation If not the RO membrane cartridge s life may be shortened and your warranty will be voided see Operating Specifications NOTE Install on cold...

Страница 4: ...4 WATER YOU CAN TRUST EVERPURE CONSERV LT S PROCESSOR 1 Secure Unit to Wall Approximately 25 lbs 11 3 kgs Operating Weight 1 3 2 Remove RO Membrane 2 3 ...

Страница 5: ...ge Tank 3 Connect Tubing for Flushing Precharge Storage Tank 5 7 psi 0 34 bar 0 034 MPa 3 8 Tubing Product Water Out 1 3 2 4 3 8 Tubing To Storage Tank 3 8 Tubing Supply Water In CLOSE OPEN 4 Prepare to Flush the Everpure 4FC5 Cartridge 1 3 2 Connect Electrical Install Bypass Plug CLOSE Unplugged Inlet Water ...

Страница 6: ...e 4FC5 Cartridge 1 2 4FC5 OPEN Plugged 1 4 Inlet Water Install Cartridge Flush to Drain Five 5 Minutes 2 3 5 Plug In Power Cord Unplug Power Cord Closed Valve As Shown 6 Prepare the Pentair GRO 75EN Cartridge for Use Replace Membrane 2 Remove Cover 1 ...

Страница 7: ...rtridge Storage Tank Not Shown 1 Remove Plug Push White 3 8 Tubing into White Connector 3 2 4 Push Red 3 8 Tubing into Red Connector Push Blue 3 8 Tubing into Blue Connector 8 Flush Pentair GRO 75EN Cartridge Plug In Power Cord Inlet Water Open Flush To Drain for 24 Hours 1 4 2 3 Fully CLOSE Turn To Right Unplug Power Cord ...

Страница 8: ...d Open 2 Solid Blue Blending Valve 1 4 Turn or Less 2 Solid Blue Blending Valve 1 4 Turn or Less 5 2 4 Repeat Until Flashing Blue Blending Valve 1 8 Turn Press Press 1 3 6 Plug In Power Cord Unplug In Power Cord OPEN One 1 Full CCW Turn of the Valve ...

Страница 9: ...9 EVERPURE CONSERV LT S HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE 10 Install Everpure 4CC Cartridge 1 2 4CC 1 Remove Port Plug 2 Install 4CC Cartridge ...

Страница 10: ...10 WATER YOU CAN TRUST 11 Flush Storage Tank and 4CC Cartridge 3 2 CLOSE OPEN 1 When Pump Turns Off OPEN valve 5 4 Plug In Power Cord Repeat Steps 2 and 4 Four 4 Times ...

Страница 11: ...more water the system is required to produce the longer the membrane will last INSTALLATION NOTE Please read all instructions specifications and precautions before installing and using your Conserv LT S Processor NOTE The Conserv LT S Processor may be installed hanging on a wall or set under a sink NOTE The Conserv LT S Processor must be installed vertically WARNING Improper connection of the appl...

Страница 12: ...er end to the Storage Tank and insert it into the ball valve The ball valve should be closed 5 Connect a length of 3 8 O D tubing to the Everpure Conserv LT S Processor outlet connection Secure an open ball valve to the other end and position it over a drain Water Supply Inlet Figure 3 4 Prepare to Flush the Everpure 4FC5 Cartridge The Everpure 4FC5 Filter Cartridge is installed and flushed before...

Страница 13: ... connect ports that are labeled Inlet White Product RO Water Blue Drain Red White Port Figure 7 CAUTION DO NOT remove the quick connect elbow fitting from the red tubing This assembly contains a flow control that may become damaged if removed The efficiency of the Everpure Conserv LT S Processor may be affected 1 Remove the GRO 75EN RO Membrane Cartridge from its packaging and position it with the...

Страница 14: ... depress blue cap Do not submerge entire unit 4 One 1 or two 2 lights will light immediately Match light s to the chart to get approximate range of Total Dissolved Solids TDS Release the blue cap and write down the TDS range 0 75 ppm solid blue 76 150 ppm flashing blue 100 250 ppm flashing blue solid green 251 300 ppm solid green 301 400 ppm flashing green 401 500 ppm solid green flashing green 50...

Страница 15: ...ck the tank air pressure Ensure that the tank has 5 7 psi 0 34 bar 0 034 MPa of precharge upon installation Add air if needed Tank pressure may be checked using an air pressure gauge on the air valve on the side of the tank Blended Water Outlet Figure 12 1 OPEN the ball valve on the top of the Storage Tank 2 CLOSE the ball valve at the blended water out tubing 3 Apply power It will take approximat...

Страница 16: ... access to the flow controller and the attached capillary tube Replace the flow controller Figure 13 in the red tubing 6 Insert a new flow controller Figure 13 with capillary tube into the tubing Replace the quick connect elbow Flow Controller Red Tubing White Tubing Blue Tubing Figure 13 7 Insert the new GRO 75EN RO Membrane Cartridge into position in the clip Rotate the cartridge so the quick co...

Страница 17: ...high quality silicone lubricant Replace the central plug assembly and insert the flushing cartridge into the left side head for the Everpure 4FC5 Cartridge NOTE Do not use petroleum jelly to lubricate the o rings It will degrade the o rings 2JT Plug 4CC Port Connect White and Blue Tubing Cartridge with Sanitizer Figure 15 6 Install a plug into the port for the 4CC Filter Cartridge NOTE A plug was ...

Страница 18: ... 3 Unscrew the tank valve from the storage tank 4 Inspect the rubber seal inside the threaded area Repair or replace the valve as needed 5 Thread the tank valve onto the top of the tank opening by turning it clockwise until snug 6 Wet the tubing and insert it 3 4 1 9 cm into the quick connect fitting 7 Turn water supply ON and CLOSE the application valve 8 Allow processor to pressurize for several...

Страница 19: ...nstallation must comply with state and local regulations Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts Substances that may be reduced are not necessarily in your water Filter must be maintained according to manufacturer s instructions including replacement of filter cartridges The efficiency rating for this system is 56 31 Efficiency ratin...

Страница 20: ...re technical service at the phone number listed below Any part found materially defective within the terms of this warranty will be repaired or replaced at PFS s discretion by your local dealer or Pentair Everpure technical service You pay only freight from our factory and local dealer charges Any item repaired or replaced pursuant to this warranty will be covered under the original warranty terms...

Отзывы: