background image

 14 

WATER YOU CAN TRUST

®

1.  Insert RO inlet connection into the white quick-connect 

port of the RO filter.

2.  Insert drain water connection into the red quick-connect 

port of the RO filter.

3.  Insert RO water connection into the blue quick-connect 

port of the RO filter.

8

 Flush the Pentair

®

 GRO-75EN RO Membrane   

Cartridge:

Blend Valve

Figure 9 

1.  Close the blend valve completely by turning it to the right 

(clockwise) until it stops.

2.  Apply power.
3.  Flush to drain for 24 hours.
4.  Turn OFF power.

USING THE TDS METER TO TEST FOR TOTAL 
DISSOLVED SOLIDS

After the processor has been flushed, it is still necessary to 

test and set the Total Dissolved Solids (TDS) to an acceptable 

level. A TDS meter is included for testing purposes.
The included TDS Meter is designed for limited use. After 

six (6) tests, the meter may not be accurate and should be 

discarded. 

Probe End

Figure 10 

NOTE: For better accuracy and frequent testing for TDS, use 

a standard pocket TDS meter.

9

 Set Blending Valve

The water exiting the Everpure

 

Conserv LT-S Processor 

should have a TDS reading of 80 ppm before the Everpure 

4CC Cartridge is added.

NOTE: The blend adjustment valve will be opened one (1) 

full turn to take the initial reading.

1.  CLOSE the blend adjustment valve, then OPEN it one (1)

full turn to the left (counterclockwise).

2.  Turn power ON and collect 1" to 2" of RO blended water 

in a clean glass container.

3.  Insert probe end of meter no more than 1" into water, 

and depress blue cap. Do not submerge entire unit.

4.  One (1) or two (2) lights will light immediately. Match 

light(s) to the chart to get approximate range of Total 

Dissolved Solids (TDS). Release the blue cap, and write 

down the TDS range.

0-75 ppm (solid blue)

76-150 ppm (flashing blue)

100-250 ppm (flashing blue + solid green)

251-300 ppm (solid green)

301-400 ppm (flashing green)

401-500 ppm (solid green + flashing green) 

501-600 ppm (flashing green + solid red)

601-750 ppm (flashing red)

751-900 ppm (solid red)

The Conserv LT-S Processor includes a blend system that 

can combine or "blend" water sources. OPENING the blend 

adjustment valve will add untreated water with higher TDS to 

the RO water.
To achieve the target TDS of 80 ppm, it is likely that the blend 

valve will need to be adjusted. Use the TDS reading from the 

previous steps as the starting point. If that number is above 

80 ppm, the blend adjustment valve will need to be closed 

slightly. If that number is below 80 ppm, the blend adjustment 

valve will need to be opened slightly.

NOTE: Changes to the blend adjustment valve should be 

made in small increments. Adjust the valve in 1/8 to 

1/4 of a rotation for best results.

The desired reading of 80 ppm is at the high end of the solid 

blue range. To be certain the blended water is at or near 80 

ppm, use the following procedure:

1.  Run blended water into a glass and collect 1" to 2"  

of water.

2.  Test this water for a TDS level. Based on the result, the 

mixing valve will be opened or closed. 
•  If the meter showed a solid blue light, then the mixing 

valve will be OPENED more.

•  If the meter showed any other indicator, then the 

mixing valve will be CLOSED more.

Содержание EVERPURE CONSERV LT-S

Страница 1: ...ounting the Conserv LT S Processor inspect the parts Use the table and illustration provided to verify the parts provided If any parts are missing contact Customer Service at 800 942 1153 US only 630 307 3000 or by email at CSeverpure pentair com Parts 1 Wall Unit with GRO 75EN RO Membrane Cartridge in Place 2 4CC Mineral Cartridge 3 4FC5 Filter Cartridge 4 Storage Tank 5 Parts Bag Containing Bypa...

Страница 2: ...s restricted to trained adult personnel No one should play with the appliance NOTE Children should be supervised to ensure that they do not play with the appliance NOTE Cleaning and user maintenance shall not be made by children without supervision NOTE The appliance is not suitable for installation in an area where a water jet could be used NOTE If the supply cord is damaged it must be replaced b...

Страница 3: ...d NOTE Substances listed as reduced are not necessarily in your water The Processor must be maintained according to manufacturer s instructions including replacement of filter cartridges NOTE Your water must be within required limits for satisfactory operation If not the RO membrane cartridge s life may be shortened and your warranty will be voided see Operating Specifications NOTE Install on cold...

Страница 4: ...4 WATER YOU CAN TRUST EVERPURE CONSERV LT S PROCESSOR 1 Secure Unit to Wall Approximately 25 lbs 11 3 kgs Operating Weight 1 3 2 Remove RO Membrane 2 3 ...

Страница 5: ...ge Tank 3 Connect Tubing for Flushing Precharge Storage Tank 5 7 psi 0 34 bar 0 034 MPa 3 8 Tubing Product Water Out 1 3 2 4 3 8 Tubing To Storage Tank 3 8 Tubing Supply Water In CLOSE OPEN 4 Prepare to Flush the Everpure 4FC5 Cartridge 1 3 2 Connect Electrical Install Bypass Plug CLOSE Unplugged Inlet Water ...

Страница 6: ...e 4FC5 Cartridge 1 2 4FC5 OPEN Plugged 1 4 Inlet Water Install Cartridge Flush to Drain Five 5 Minutes 2 3 5 Plug In Power Cord Unplug Power Cord Closed Valve As Shown 6 Prepare the Pentair GRO 75EN Cartridge for Use Replace Membrane 2 Remove Cover 1 ...

Страница 7: ...rtridge Storage Tank Not Shown 1 Remove Plug Push White 3 8 Tubing into White Connector 3 2 4 Push Red 3 8 Tubing into Red Connector Push Blue 3 8 Tubing into Blue Connector 8 Flush Pentair GRO 75EN Cartridge Plug In Power Cord Inlet Water Open Flush To Drain for 24 Hours 1 4 2 3 Fully CLOSE Turn To Right Unplug Power Cord ...

Страница 8: ...d Open 2 Solid Blue Blending Valve 1 4 Turn or Less 2 Solid Blue Blending Valve 1 4 Turn or Less 5 2 4 Repeat Until Flashing Blue Blending Valve 1 8 Turn Press Press 1 3 6 Plug In Power Cord Unplug In Power Cord OPEN One 1 Full CCW Turn of the Valve ...

Страница 9: ...9 EVERPURE CONSERV LT S HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE 10 Install Everpure 4CC Cartridge 1 2 4CC 1 Remove Port Plug 2 Install 4CC Cartridge ...

Страница 10: ...10 WATER YOU CAN TRUST 11 Flush Storage Tank and 4CC Cartridge 3 2 CLOSE OPEN 1 When Pump Turns Off OPEN valve 5 4 Plug In Power Cord Repeat Steps 2 and 4 Four 4 Times ...

Страница 11: ...more water the system is required to produce the longer the membrane will last INSTALLATION NOTE Please read all instructions specifications and precautions before installing and using your Conserv LT S Processor NOTE The Conserv LT S Processor may be installed hanging on a wall or set under a sink NOTE The Conserv LT S Processor must be installed vertically WARNING Improper connection of the appl...

Страница 12: ...er end to the Storage Tank and insert it into the ball valve The ball valve should be closed 5 Connect a length of 3 8 O D tubing to the Everpure Conserv LT S Processor outlet connection Secure an open ball valve to the other end and position it over a drain Water Supply Inlet Figure 3 4 Prepare to Flush the Everpure 4FC5 Cartridge The Everpure 4FC5 Filter Cartridge is installed and flushed before...

Страница 13: ... connect ports that are labeled Inlet White Product RO Water Blue Drain Red White Port Figure 7 CAUTION DO NOT remove the quick connect elbow fitting from the red tubing This assembly contains a flow control that may become damaged if removed The efficiency of the Everpure Conserv LT S Processor may be affected 1 Remove the GRO 75EN RO Membrane Cartridge from its packaging and position it with the...

Страница 14: ... depress blue cap Do not submerge entire unit 4 One 1 or two 2 lights will light immediately Match light s to the chart to get approximate range of Total Dissolved Solids TDS Release the blue cap and write down the TDS range 0 75 ppm solid blue 76 150 ppm flashing blue 100 250 ppm flashing blue solid green 251 300 ppm solid green 301 400 ppm flashing green 401 500 ppm solid green flashing green 50...

Страница 15: ...ck the tank air pressure Ensure that the tank has 5 7 psi 0 34 bar 0 034 MPa of precharge upon installation Add air if needed Tank pressure may be checked using an air pressure gauge on the air valve on the side of the tank Blended Water Outlet Figure 12 1 OPEN the ball valve on the top of the Storage Tank 2 CLOSE the ball valve at the blended water out tubing 3 Apply power It will take approximat...

Страница 16: ... access to the flow controller and the attached capillary tube Replace the flow controller Figure 13 in the red tubing 6 Insert a new flow controller Figure 13 with capillary tube into the tubing Replace the quick connect elbow Flow Controller Red Tubing White Tubing Blue Tubing Figure 13 7 Insert the new GRO 75EN RO Membrane Cartridge into position in the clip Rotate the cartridge so the quick co...

Страница 17: ...high quality silicone lubricant Replace the central plug assembly and insert the flushing cartridge into the left side head for the Everpure 4FC5 Cartridge NOTE Do not use petroleum jelly to lubricate the o rings It will degrade the o rings 2JT Plug 4CC Port Connect White and Blue Tubing Cartridge with Sanitizer Figure 15 6 Install a plug into the port for the 4CC Filter Cartridge NOTE A plug was ...

Страница 18: ... 3 Unscrew the tank valve from the storage tank 4 Inspect the rubber seal inside the threaded area Repair or replace the valve as needed 5 Thread the tank valve onto the top of the tank opening by turning it clockwise until snug 6 Wet the tubing and insert it 3 4 1 9 cm into the quick connect fitting 7 Turn water supply ON and CLOSE the application valve 8 Allow processor to pressurize for several...

Страница 19: ...nstallation must comply with state and local regulations Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts Substances that may be reduced are not necessarily in your water Filter must be maintained according to manufacturer s instructions including replacement of filter cartridges The efficiency rating for this system is 56 31 Efficiency ratin...

Страница 20: ...re technical service at the phone number listed below Any part found materially defective within the terms of this warranty will be repaired or replaced at PFS s discretion by your local dealer or Pentair Everpure technical service You pay only freight from our factory and local dealer charges Any item repaired or replaced pursuant to this warranty will be covered under the original warranty terms...

Отзывы: