PB-1525 Wood Pellet Burner System: Installation and Operation Manual
Rev 1.0, OCTOBER 2011
Page 52 of 67
burn chamber. The
error message
suggests that the
system has run out
of fuel.
Sensor
4.
Failed Blower
5.
Improper draft in
system
3.
CP* install new
flame sensor
4.
CP* install new
blower
5.
CP* checking of
draft and
cleaning of boiler
Flame sensed-
short?
Error occurs as a
result of the burner
failing to sense the
extinguishing of
flame within the
burn chamber
within the
prescribed amount
of time during the
shut down cycle.
The error message
suggests a flame
sensor short as a
potential cause.
1.
Burn filled with
clinkers
2.
Failed Flame
Sensor
3.
Foreign light
introduced to
burn chamber
1.
Clean burn
chamber and
restart system
2.
CP* install new
flame sensor
3.
Ensure burner
cover is properly
installed; do not
shine direct &
intense light into
the burner cover
or boiler/furnace
firebox.
Flame seen at idle
Error occurs as a
result of the burner
sensing flame within
the burn chamber
while the system is in
the Idle State.
1.
Burn filled with
clinkers
2.
Failed Flame
Sensor
3.
Foreign light
introduced to
burn chamber
1.
Clean burn
chamber and
restart system
2.
CP* install new
flame sensor
3.
Ensure burner
cover is
properly
installed; do
not shine
direct &
intense light
into the burner
cover or