PB-1525 Wood Pellet Burner System: Installation and Operation Manual
Rev 1.0, OCTOBER 2011
Page 50 of 67
Disable the system by pressing and holding the “Disa” button on the
controller for 5-6 seconds; or as soon as the “Ena” display appears. If the
burner has just been in operation, wait 10-20 minutes before cleaning to
allow the combustion chamber to cool down. Follow these steps:
1.
Remove the two cables from the burner,
2.
Loosen the two wing nuts on the top of the burner,
3.
Remove the wing nut on the back side of the burner,
4.
Remove the green burner cover,
5.
Release the two quick latches located on each side of the burner,
6.
Bend burner forward slightly, rotating about the drop and lift from
assembly,
7.
Remove the burner chamber by sliding it from within the assembly,
8.
Dump contents of the burner chamber into a properly rated ash
can. Scrape or brush the chamber as necessary and re-assemble
the burner.
IMPORTANT: Remember to Enable to system by pressing and holding the
“Ena” button on the controller for 5-6 seconds; or as soon as the “Disa”
display appears. Failure to re-enable the system will leave you without
heat as the system will not fire in the Disabled state.
WARNING!
Never store ashes and/or clinkers inside the building or in a non-
metallic container rated for the storage of hot coals. Always use
a container specifically rated for the removal of ash. Ashes and
clinkers within the burner can appear to be cool; however, once
exposed to air and broken up during the cleaning process can
be hot enough to start a fire.
CAUTION!
Burner components may be very hot. Always check the
temperature of the burn chamber before removing from the
system. Use gloves or other protective gear to avoid injury.