3.3.
AC Voltage/DC V AC Voltage
Range
Resolution
Accuracy
40 Hz - 6 kHz
6 kHz
– 20 kHz
20 kHz
– 600 kHz
600 mV
0,01 mV
± (0,8% + 80 dgt.)
unspecified
unspecified
6 V
0,1 mV
± (1% + 80 dgt.)
± (2,5% +80 dgt.)
60 V
1 mV
600 V
10 mV
unspecified
1000 V
0,1 V
unspecified
unspecified
Note
: Accuracy can be guaranteed within 10% to 100% of full range.
3.4. DC Voltage
Range
Resolution
Accuracy
60 mV
0,001 mV
± (0,03% + 10 dgt.)
600 mV
0,01 mV
± (0,03% + 6 dgt.)
6 V
0,1 mV
60 V
1 mV
600 V
10 mV
1000 V
0,1 V
Note
: Accuracy can be guaranteed within the full range.
3.5. AC Current
Range
Resolution
Accuracy
Voltage Drop
60 Hz ~ 6 kHz
6 kHz ~ 60 kHz
600 µA 0,01 µA
± (0,8% + 80 dgt.)
± (1,2% + 80 dgt.)
50 µV/µA
6000 µA 0,1 µA
60 mA 1 µA
0,5 mV/mA
600 mA 10 µ
6 A 0,1 mA
5 mV/A
10 A 1 mA
± (1,0% + 80 dgt.)
± (1,5% + 80 dgt.)
Note
: Accuracy can be guaranteed within 10% to 100% of full range.
3.6. DC Current
Range
Resolution
Accuracy
Voltage Drop
600 µA
0,01 µA
± (0,15% + 15 dgt.)
50 µV/µA
6000 µA
0,1 µA
± (0,15% + 10 dgt.)
60 mA
1 µA
0,5 mV/mA
600 mA
10 µA
6 A
0,1 mA
± (0,5% + 10 dgt.)
5 mV/A
10 A
1 mA
Note
: Accuracy can be guaranteed within the full range.