99
4061
w/
r
2001...
...2099
-
Current year in YYYY format
4062
w/
r
0...1
0
Auto change of summer/winter time and vice versa
Value
Description
0
Switched off
1
Switched on
4063
w/
r
-
RESERVED
4064
Arch.Val
w/
r
0...2
0
Select archived values
Note:
changing register value clears the archive
in the internal memory!!!
Value
Description
0
displayed value only – value calculated
from the main input
1
displayed value and second displayed
value
2
displayed value, second displayed value
and all quired registers in
Master
or
Monitor
RS-485 mode
4065
Param.Ar
w/
r
0...2
0
Type of input value which controls conditional
archiving
Value
Description
0
displayed value – value calculated from
the main input
1
time
2
the second displayed value
4066
Ar. Mode
w/
r
0...5
5
Archiving triggering condition (Description –
section.5.8)
Value
Description
0
n-on
1
n-off
2
on
3
off
4
h-on
5
h-off