WAN Serial Port Configuration
43
Models 2603, 2621, and 2635 User Manual
5
• Serial Port Configuration
WAN Serial Port Configuration
The OnSite Series routers use a sync.-serial interface (X.21, V.35) or a T1/E1 interface for connection to stan-
dard WAN services. Below are the configuration options for the WAN interface.
Serial Interface
The serial interface configuration menus allow the user to configure the serial interface for HDLC based con-
nections.
Variables
The following table lists variables that are configurable on the OnSite device’s software:
Variable
Options
Function
Clock Mode
Internal
The clock setting for the serial interface will determine the
source of timing for the serial interface only.
External
RX Clock Invert / TX
Clock Invert
Inverted
The clock invert functions could be used to invert the clocks
that are used on the serial interface. It is not recommended
to change this parameter unless requested by Patton Elec-
tronics’ technical support. Keep at default.
Normal
Serial Speed
Any n x 64 kbps speed.
Speed should be enter-
ed as the rate, i.e.
512
for 512 kbps or
2048
for
2.048 Mbps
Defines the generated speed for internal clock mode opera-
tion or the clock that will be received in external clock mode
operation.
TX Data Sample-
Point
Ext Clk
When the unit is running in internal clock mode, the setting
of TX Data SamplePoint will indicate to the system which
clock to use to sample the in coming data. Some systems
require that the data be sampled on one clock or another.
This is also useful when tail circuits are being created.
When running in the external clock mode this should be set
to Ext Clk.
Tx Clk
Содержание OnSite 2603
Страница 23: ...23 Chapter 2 Product Overview Chapter contents Introduction 24 Applications Overview 25...
Страница 38: ...38 Chapter 4 Ethernet LAN Port Chapter contents Introduction 39 LAN Connections 39 Ethernet Port 39...
Страница 120: ...120 Appendix C Cable Recommendations Chapter contents Ethernet Cable 121 Adapter 121...