Introduction
186
IPLink Software Configuration Guide
16 • T1/E1 port configuration
Introduction
This chapter provides an overview of the T1/E1 ports, their characteristics and the tasks involved in
the configuration.
The configurable parameters for the T1/E1 port are type (T1 or E1), clock mode (or source) (master or slave),
line code (AMI, HDB3, or B8ZS), framing (CRC-4, ESF, or unframed), line-build-out (for T1 only) and
encapsulation (channelized or HDLC).
A further feature is the creation and configuration of channel-groups.
T1/E1 port configuration task list
This section describes the configuration tasks for the T1/E1 port.
•
Enable/Disable T1/E1 port
•
Configuring the T1/E1 port type
•
Configuring T1/E1 clock mode
•
Configuring T1/E1 line code
•
Configuring T1/E1 framing
•
Configuring T1 line build out (LBO) (T1 only)
•
Configuring E1 impedance/connector
•
Configuring T1/E1 application mode
•
Configuring T1/E1 LOS threshold
•
Configuring T1 Loopback detection (T1 only)
•
Configuring T1/E1 encapsulation
•
Create a Channel-Group
•
Configuring channel-group timeslots
•
Configuring channel-group encapsulation
•
Entering HDLC configuration mode
•
Configuration HDLC CRC-type
•
Configuring HDLC encapsulation
Enable/Disable T1/E1 port
By default, the T1/E1 port is disabled. The following command is used for enabling or disabling it.
Mode: port e1t1 <slot> <port>
Step
Command
Purpose
1
[
name
] (prt-e1t1)[
slot/port
]# [no]
shutdown
Enable/Disable the T1/E1 port.
Default:
shutdown
(which is disabled)
Содержание IPLink Series
Страница 309: ...309 Appendix B Mode summary Chapter contents Introduction 310...
Страница 312: ...Introduction 312 IPLink Software Configuration Guide B Mode summary...
Страница 325: ...325 Appendix D Internetworking terms acronyms Chapter contents Abbreviations 326...
Страница 330: ...330 Appendix E Used IP ports in the IPLink software Chapter contents Used IP ports in the IPLink software 331...