APPENDIX A

PATTON MODEL 2530 SPECIFICATIONS

Compatibility:

AT&T 62310

DDS Line Interface:

Externally accessible RJ-48S

Transmission Format:

Synchronous or asynchronous

Transmission Line:

Two unconditioned twisted pair

Clock Options:

Internal, external, receive loopback and
campus

DTE/DCE Interfaces:

Patton 

QuikConnect™  Modules: EIA 

RS-232/CCITT V.24, RS-232/530, 
CCITT V.35 and  CCITT X.21 

DTE/DCE Speeds:

Synchronous: 2.4, 4.8, 9.6, 19.2, 56, 
and 64 kbps;
Asychronous: 2.4, 4.8, 9.6, 19.2, 38.4, 
and 57.6 kbps

Diagnostics:

V.54 compliant local and remote 
loopbacks; V.52 compliant 511 and 
2047 BER tests

Front Panel LEDs:

DDS line rates (2.4, 4.8, 9.6, 19.2, 
56, and  64 kbps), Power, TD, RD, 
RTS, CTS, DCD, DSR, DTR, No 
Signal, Test Mode, Error indication.

Distance:

-49 dBm receiver sensitivity or better 

RTS/CTS Delay:

0 ms/30 ms 

Front Panel Switches:

Loopback indication and Bit Error Rate 
Test

Power:

Universal Input (UI): 100 - 253VAC 
Input; DC: 18VDC - 72VDC, 48V 
Nominal

Temperature Range:

32-122°F (0° -50°C) 

Altitude:

0-15,000 feet

Humidity:

5 to 95% noncondensing

Dimensions:

7.3” x 6.6” x 1.62” (185mm x 168mm x 
41mm)

Weight:

2.01 lbs. (1.0kg)

Approvals:

FCC Part 68, FCC Part 15, UL and cUL
Approvals.

Surge Protection:

600W Power Dissipation

Lightning Protection:

Gas Tube

Isolation:

1500V via Isolation Transformers

29

APPENDIX B

PATTON MODEL 2530 FACTORY REPLACEMENT PARTS

AND ACCESSORIES

Patton Model #

Description

IM1/A...............................V.24 with DB25F
IM1/B ...............................RS422/RS530 with DB25F
IM1/C...............................V.35 with M34F
IM1/D...............................X.21 with DB15F
IM1/E ...............................V.35 with DB25F
IM1/F ...............................G.703 with RJ45
IM1/G...............................High Speed Asynchronous with DB-25F
0805US ...........................American Power Cord
0805EUR.........................European Power Cord CEE 7
0805UK ...........................United Kingdom Power Cord
0805AUS .........................Australia/New Zealand Power Cord
0805DEN.........................Denmark Power Cord
0805FR............................France/Belgium Power Cord
0805IN.............................India Power Cord
0805IS .............................Israel Power Cord
0805JAP ..........................Japan Power Cord
0805SW...........................Switzerland Power Cord
07M2530 .........................User Manual
07M1090SVC ..................1090 Series Service Manual

30

Data
Rate

64 Kbps

7.1

4.9

3.4

56 Kbps

7.6

5.2

3.6

19.2 Kbps

8.7

6.2

4.5

9600 bps

10.4

7.7

5.8

4800 bps

13.7

10.6

9.7

2400 bps

15.1

14.2

9.1

Model 2530 Series Distance Table (miles)

Wire Gauge

22

24

26

Содержание DigiLink-V 2530

Страница 1: ...MODEL 2530 DigiLink V All Rate DDS CSU DSU SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2530 B Doc 099101UB Revised 02 09 99 C E R T I F I E D An ISO 9001 Certi...

Страница 2: ...uct These damages include but are not limited to the following lost profits lost savings and incidental or consequen tial damages arising from the use of or inability to use this product Patton Electr...

Страница 3: ...of this Patton Electronics product This product has been thoroughly inspected and tested and is warrant ed for One Year parts and labor If any questions or problems arise during installation or use of...

Страница 4: ...itches S1 1 and S1 2 to configure the DTE rate of the Model 2530 This rate represents the synchronous or asynchronous rate at which the DTE must connect to Model 2530 s QuikConnect interface S1 1 S1 2...

Страница 5: ...1 start bit 8 data bits 1 stop bit 0 parity bits 10 bits 7 Switch S1 8 Extended Signaling Rate Use S1 8 to configure the frequency tolerence the Model 2530 looks for in asynchronous data rates i e the...

Страница 6: ...lways ON Off Follows The RTS input controls the DTE Signal transmitter NOTE At 64 kbps Force RTS is always on 9 Switch S2 7 Data Set Ready During LOCAL Loopback Test Use Switch S2 7 to control the beh...

Страница 7: ...able or disable the front panel switches S3 3 Activation Description Off Enabled Front panel switches may be used to activate terminate diagnostics On Disabled Front panel switches will have no effect...

Страница 8: ...tial login pass word is PATTON NOTE We recommend that you change this password after the initial login 7 The 2530 will then display the MAIN MENU screen 13 3 2 1 Introduction to MAIN MENU The MAIN MEN...

Страница 9: ...3 1 to review the hard ware switch definitions To modify any of the parameters listed above 1 Key the highlighted letter that corresponds to a menu selection 2 Press Space Bar until the desired value...

Страница 10: ...P Switch 3 4 is ON 1 Key the highlighted letter that corresponds to a menu selection 2 Press Space Bar until the desired value is highlighted 3 Press Enter CR to select the desired value Change Passwo...

Страница 11: ...ge connector on one side and a serial port interface on the other Figure 3 below shows how a QuikConnect Module plugs into the back of the Model 2530 4 1 1 Changing QuikConnect Modules When you purcha...

Страница 12: ...his cable should be of the shortest possible length we recommend 6 feet or less When purchasing or constructing a null modem interface cable use the pin diagrams in Appendix D as a guide NOTE Pin out...

Страница 13: ...features twenty four 24 front panel LEDs that monitor the line rate power the DTE signals the network connection and test modes Figure 5 below shows the front panel location of each LED Following Figu...

Страница 14: ...ppendix D 25 2 Verify that the data terminal equipment is operating properly and can be used for a test 3 Perform a V 52 BER bit error rate test as described in Section 5 3 3 If the BER test equipment...

Страница 15: ...d the communication link s are functioning properly 511 Initiates a built in 511 bit pseudo random pattern generator and detector 511 with Errors Initiates a built in 511 bit pseudo random pattern gen...

Страница 16: ...F 0 50 C Altitude 0 15 000 feet Humidity 5 to 95 noncondensing Dimensions 7 3 x 6 6 x 1 62 185mm x 168mm x 41mm Weight 2 01 lbs 1 0kg Approvals FCC Part 68 FCC Part 15 UL and cUL Approvals Surge Prot...

Страница 17: ...19 RTS Request to Send 20 DTR Data Terminal Ready 21 DL Remote Digital Loop 22 DSR Data Set Ready 23 DTR Data Terminal Ready B 24 XTC External Transmit Clock 25 TM Test Mode 31 APPENDIX C PATTON MODEL...

Страница 18: ...eive Data A 5 I Indication A 6 S Signal Element iming A 8 SGND Signal Ground 9 T Transmit Data B 10 C Control B 11 R Receive Data B 12 I Indication B 13 S Signal Element Timing B 33 APPENDIX D PATTON...