4.3  CONNECTING POWER 

The Model 2530 is available with two power supply options:

4.3.1   Connecting to an AC Power Source

Universal Interface AC Power Supply option (Model 2530-UI)

operates in environments ranging from 100 to 253 VAC, with no re-con-
figuration necessary (see Appendix B for available domestic and inter-
national power cords). To connect the standard or universal power
supply, follow these steps:

1)

Attach the power cord (supplied) to the shrouded male IEC-

320 

connector on the rear of the Model 2530.

2)

Plug the power cord into a nearby AC power outlet.

3)

Turn the rear power switch ON.

4.3.2   Connecting to a DC Power Source

DC Power Supply option (Model 2530-DC) operates in 48 VDC

environments and is equipped with a 3-pin “terminal strip” style con-
nector. The 48 VDC power supply option uses a 3-pin terminal block
with spring-type connectors. Please refer to the Model 2530 Series
Service Manual for further instructions.

23

5.0  OPERATION

After the Model 2530 is properly configured and installed, it should

operate transparently. This sections describes power-up, the LED sta-
tus monitors, and the built-in loopback test modes.

5.1  POWER-UP

To apply power to the Model 2530, first be sure that you have read

Section 4.3, and that the unit is connected to the appropriate power
source. Then power-up the unit using the rear power switch.

5.2  LED STATUS MONITORS

The Model 2530 features twenty-four (24) front panel LEDs that

monitor the line rate, power, the DTE signals, the network connection
and test modes. Figure 5 (below) shows the front panel location of
each LED. Following Figure 5 is a description of each LEDs function.

Power

Glows green when power is present.

Line Rate

The corresponding LED will glow red to indicate the 
selected line rate.

TD & RD

Glows red to indicate an idle condition of Binary 
“1” data on the respective terminal interface signals.
Green indicates Binary “0” data.

RTS

Glows green to indicate that the Request to Send 
signal from the DTE is active.

CTS

Glows green to indicate that the Clear to Send 
signal from the modem is active.

DSR

Glows green to indicate that the 2530 has asserted 
the Data Set Ready signal.

DCD

Glows red if no carrier signal is being received from 
the remote modem. Green indicates that the remote 
modem’s carrier is being received.

24

WARNING!

There are no user-serviceable parts in the

power supply section of the Model 2530. Voltage setting
changes and fuse replacement should only be performed   by
qualified service personnel. Contact Patton Electronics
Technical support at (301) 975-1007, via our website at
http://www.patton.com, or by e-mail at [email protected],
for more information.

Model 2530

 

DigiLink-V  Dedicated CSU/DSU

Test Mode

Error

No Signal

DTR

DSR

DCD

CTS

RTS

RD

TD

2.4 kbps

4.8 kbps

9.6 kbps

19.2 kbps

38.4 kbps

56 kbps

64    kbps

Power

Test Modes

Loop             Pattern

Line

Status

Line Rate

DTE Status

Control Port

Local -

Normal -

Remote -

- Errored

- Off

- Normal

Figure 5. Model 2530 Front Panel Installation of Model 

Содержание DigiLink-V 2530

Страница 1: ...MODEL 2530 DigiLink V All Rate DDS CSU DSU SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2530 B Doc 099101UB Revised 02 09 99 C E R T I F I E D An ISO 9001 Certi...

Страница 2: ...uct These damages include but are not limited to the following lost profits lost savings and incidental or consequen tial damages arising from the use of or inability to use this product Patton Electr...

Страница 3: ...of this Patton Electronics product This product has been thoroughly inspected and tested and is warrant ed for One Year parts and labor If any questions or problems arise during installation or use of...

Страница 4: ...itches S1 1 and S1 2 to configure the DTE rate of the Model 2530 This rate represents the synchronous or asynchronous rate at which the DTE must connect to Model 2530 s QuikConnect interface S1 1 S1 2...

Страница 5: ...1 start bit 8 data bits 1 stop bit 0 parity bits 10 bits 7 Switch S1 8 Extended Signaling Rate Use S1 8 to configure the frequency tolerence the Model 2530 looks for in asynchronous data rates i e the...

Страница 6: ...lways ON Off Follows The RTS input controls the DTE Signal transmitter NOTE At 64 kbps Force RTS is always on 9 Switch S2 7 Data Set Ready During LOCAL Loopback Test Use Switch S2 7 to control the beh...

Страница 7: ...able or disable the front panel switches S3 3 Activation Description Off Enabled Front panel switches may be used to activate terminate diagnostics On Disabled Front panel switches will have no effect...

Страница 8: ...tial login pass word is PATTON NOTE We recommend that you change this password after the initial login 7 The 2530 will then display the MAIN MENU screen 13 3 2 1 Introduction to MAIN MENU The MAIN MEN...

Страница 9: ...3 1 to review the hard ware switch definitions To modify any of the parameters listed above 1 Key the highlighted letter that corresponds to a menu selection 2 Press Space Bar until the desired value...

Страница 10: ...P Switch 3 4 is ON 1 Key the highlighted letter that corresponds to a menu selection 2 Press Space Bar until the desired value is highlighted 3 Press Enter CR to select the desired value Change Passwo...

Страница 11: ...ge connector on one side and a serial port interface on the other Figure 3 below shows how a QuikConnect Module plugs into the back of the Model 2530 4 1 1 Changing QuikConnect Modules When you purcha...

Страница 12: ...his cable should be of the shortest possible length we recommend 6 feet or less When purchasing or constructing a null modem interface cable use the pin diagrams in Appendix D as a guide NOTE Pin out...

Страница 13: ...features twenty four 24 front panel LEDs that monitor the line rate power the DTE signals the network connection and test modes Figure 5 below shows the front panel location of each LED Following Figu...

Страница 14: ...ppendix D 25 2 Verify that the data terminal equipment is operating properly and can be used for a test 3 Perform a V 52 BER bit error rate test as described in Section 5 3 3 If the BER test equipment...

Страница 15: ...d the communication link s are functioning properly 511 Initiates a built in 511 bit pseudo random pattern generator and detector 511 with Errors Initiates a built in 511 bit pseudo random pattern gen...

Страница 16: ...F 0 50 C Altitude 0 15 000 feet Humidity 5 to 95 noncondensing Dimensions 7 3 x 6 6 x 1 62 185mm x 168mm x 41mm Weight 2 01 lbs 1 0kg Approvals FCC Part 68 FCC Part 15 UL and cUL Approvals Surge Prot...

Страница 17: ...19 RTS Request to Send 20 DTR Data Terminal Ready 21 DL Remote Digital Loop 22 DSR Data Set Ready 23 DTR Data Terminal Ready B 24 XTC External Transmit Clock 25 TM Test Mode 31 APPENDIX C PATTON MODEL...

Страница 18: ...eive Data A 5 I Indication A 6 S Signal Element iming A 8 SGND Signal Ground 9 T Transmit Data B 10 C Control B 11 R Receive Data B 12 I Indication B 13 S Signal Element Timing B 33 APPENDIX D PATTON...

Отзывы: