Diagnostics/Statistics
Select “Diagnostics/Statistics” from MAIN MENU to monitor or acti-
vate/deactivate Model 2530’s V.52 BER test patterns and V.54 loop
diagnostics. These diagnostics and statistics can help to verify link
integrity and isolate communication difficulties .
Active Loop Conditions are shown below:
Local
Local Analog Loopback test is active.
Remote
Remote Digital Loopback is active.
Under Remote Loop The remote Model 2530 has initiated a
Remote Digital Loopback test.
Under CO Loop
The CO has initiated a CSU Loop
17
Test Patterns are shown below:
511
The 511 BER test is active.
511/E
The 511/E BER test is active.
2047
The 2047 BER test is active.
2047/E
The 2047/E BER test is active.
To activate a loop diagnostic or test pattern:
1. Make sure DIP Switch 3-4 is ON.
1. Key the highlighted letter that corresponds to a menu selection.
2. Press [Space Bar] until the desired value is highlighted.
3. Press <Enter/CR> to select the desired value.
Change Password
Select Change Password to change the active password of the
software configuration menu (see below).
To change the active password:
a.
Enter from one (1) to six (6) alphanumeric ASCII characters
(0...9, a...z, or A...Z) at the
New Password>_
prompt.
b.
Press <Enter/CR>
18
e
Diagnostics and Statistics
a
Select Active Loop
Local
b
Select Test Pattern
None
Status
Active Loop
Local
Active Test Pattern
None
Errored Seconds
0000
CD
ON
RTS
ON
CTS
ON
Select=[Highlighted Letter]
Scroll Options=[Space Bar]
Exit=[ESC]
Change Selection=[CR]
Clear Errored Seconds = [ c ]
TOP LEVEL MANAGEMENT
UNDER SOFTWARE CONTROL
a
Software Control
b
Hardware Control
c
Display Hardware Configuration
d
Software Configuration
e
Diagnostics/Statistics
f
Save Changes
g
Logoff
h
Change Password
New Password>_
f