manualshive.com logo in svg
background image

3.1.3  DIP Switch Set “S3”

The configuration switches on S3 set the BER Test pattern,

response to remote loop, front panel switch activation, DTE loop
request, and control port speed. The default settings and detailed
descriptions for each switch in the set are shown below.

Switch S3-1: Test Pattern

Use Switch S3-1 to set the V.52-compliant pattern used to test the

Model 2530. The two test options are the 511 and 2047 BER patterns
(For descriptions of the 511 and 2047 BER options, please refer to
Section 5.4).

S3-2

Setting

Off

511 Pattern

On

2047 Pattern

Switch S3-2: Response to RDL Request

Use Switch S3-2 to allow Model 2530 to enter the Remote Digital

Loopback diagnostic test when requested to do so by the remote
Model 2530  For example, when Switch S1-8 is set to “ON”, it will enter
RDL mode (See Section 5.3.2) when requested to do so by the remote
Model 2530.

S3-2

Setting

Off

Response to RDL Request Enabled

On

Response to RDL Request Disabled

11

Switch S3-3: Front Panel Switch Enable/Disable

Use Switch S3-3 to enable or disable the front panel switches.

S3-3

Activation

Description

Off

Enabled

Front panel switches may be used 
to activate/terminate diagnostics

On

Disabled

Front panel switches will have no 
effect on operation of the unit

Switch S3-4: DTE Loop Request Line Enable/Disable

Use Switch S3-4 to activate or deactivate DTE control of the loop-

back diagnostic modes and BER test patterns.

DTE TM Line

S3-4

Activation

Description

Off

Enabled

DTE Loop request lines may be 
used to activate/terminate 
diagnostics.

On

Disabled

DTE loop request lines will 
have no effect on operation of 
the unit.

Switches S3-5 and S3-6:

Reserved for Future Use

Switches S3-5 and S3-6 are 

reserved for future use and must

remain in the OFF position.

Switches S3-7 and S3-8: Control Port Data Rate

Use Switches S3-7 and S3-8 to configure Model 2530’s control

port bit rate.

S3-7

S3-8

Setting

On

Off

9.6 kbps

Off

Off

19.2 kbps

12

S3 SUMMARY TABLE

Position

Function

Factory Default

S3-1

Test Pattern

Off

511

S3-2

RDL Response

Off

Enabled 

S3-3

Front Panel Switches

Off

Enabled

S3-4

DTE Loop Request

On

Disabled

S3-5

Reserved for Future Use

Off

S3-6

Reserved for Future Use

Off

S3-7

Control Port Speed

Off

S3-8

Control Port Speed

Off

19.2 kbps

}

Содержание DigiLink-V 2530

Страница 1: ...MODEL 2530 DigiLink V All Rate DDS CSU DSU SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2530 B Doc 099101UB Revised 02 09 99 C E R T I F I E D An ISO 9001 Certi...

Страница 2: ...uct These damages include but are not limited to the following lost profits lost savings and incidental or consequen tial damages arising from the use of or inability to use this product Patton Electr...

Страница 3: ...of this Patton Electronics product This product has been thoroughly inspected and tested and is warrant ed for One Year parts and labor If any questions or problems arise during installation or use of...

Страница 4: ...itches S1 1 and S1 2 to configure the DTE rate of the Model 2530 This rate represents the synchronous or asynchronous rate at which the DTE must connect to Model 2530 s QuikConnect interface S1 1 S1 2...

Страница 5: ...1 start bit 8 data bits 1 stop bit 0 parity bits 10 bits 7 Switch S1 8 Extended Signaling Rate Use S1 8 to configure the frequency tolerence the Model 2530 looks for in asynchronous data rates i e the...

Страница 6: ...lways ON Off Follows The RTS input controls the DTE Signal transmitter NOTE At 64 kbps Force RTS is always on 9 Switch S2 7 Data Set Ready During LOCAL Loopback Test Use Switch S2 7 to control the beh...

Страница 7: ...able or disable the front panel switches S3 3 Activation Description Off Enabled Front panel switches may be used to activate terminate diagnostics On Disabled Front panel switches will have no effect...

Страница 8: ...tial login pass word is PATTON NOTE We recommend that you change this password after the initial login 7 The 2530 will then display the MAIN MENU screen 13 3 2 1 Introduction to MAIN MENU The MAIN MEN...

Страница 9: ...3 1 to review the hard ware switch definitions To modify any of the parameters listed above 1 Key the highlighted letter that corresponds to a menu selection 2 Press Space Bar until the desired value...

Страница 10: ...P Switch 3 4 is ON 1 Key the highlighted letter that corresponds to a menu selection 2 Press Space Bar until the desired value is highlighted 3 Press Enter CR to select the desired value Change Passwo...

Страница 11: ...ge connector on one side and a serial port interface on the other Figure 3 below shows how a QuikConnect Module plugs into the back of the Model 2530 4 1 1 Changing QuikConnect Modules When you purcha...

Страница 12: ...his cable should be of the shortest possible length we recommend 6 feet or less When purchasing or constructing a null modem interface cable use the pin diagrams in Appendix D as a guide NOTE Pin out...

Страница 13: ...features twenty four 24 front panel LEDs that monitor the line rate power the DTE signals the network connection and test modes Figure 5 below shows the front panel location of each LED Following Figu...

Страница 14: ...ppendix D 25 2 Verify that the data terminal equipment is operating properly and can be used for a test 3 Perform a V 52 BER bit error rate test as described in Section 5 3 3 If the BER test equipment...

Страница 15: ...d the communication link s are functioning properly 511 Initiates a built in 511 bit pseudo random pattern generator and detector 511 with Errors Initiates a built in 511 bit pseudo random pattern gen...

Страница 16: ...F 0 50 C Altitude 0 15 000 feet Humidity 5 to 95 noncondensing Dimensions 7 3 x 6 6 x 1 62 185mm x 168mm x 41mm Weight 2 01 lbs 1 0kg Approvals FCC Part 68 FCC Part 15 UL and cUL Approvals Surge Prot...

Страница 17: ...19 RTS Request to Send 20 DTR Data Terminal Ready 21 DL Remote Digital Loop 22 DSR Data Set Ready 23 DTR Data Terminal Ready B 24 XTC External Transmit Clock 25 TM Test Mode 31 APPENDIX C PATTON MODEL...

Страница 18: ...eive Data A 5 I Indication A 6 S Signal Element iming A 8 SGND Signal Ground 9 T Transmit Data B 10 C Control B 11 R Receive Data B 12 I Indication B 13 S Signal Element Timing B 33 APPENDIX D PATTON...