Fault analysis
73
Model 3096RC T-DAC Getting Started Guide
5 • Troubleshooting and maintenance
Fault analysis
The following procedures outline steps you should follow when troubleshooting a Model 3096RC malfunction.
1. If possible, talk to the person who filed the trouble complaint and determine the operational symptoms.
Record the symptoms on the appropriate trouble report form (include the front panel LED indications).
2. Refer to
table 8
for LED definitions and compare the recorded results from the trouble report against those
in the table, then refer to the section recommended in the table for the maintenance procedure that will
repair the malfunction.
Table 8. LED definitions
LED
Location
Color
Status
Meaning
POWER
Front
panel
Green
On
solid
Power is being applied. No action recommended.
Flashing The 3096RC has detected a power failure on a power bus. There
may be a problem with the CPCI power supply system such as a
failed power supply module in the chassis. The Model 3096RC
will function normally with one power supply. Inspect the power
supplies in the CPCI chassis to identify and replace the failed
power supply module. If the POWER LED continues flashing
when all chassis power supplies are functional, contact Patton
Technical Support to determine if the T-DAC should be replaced.
Off
No input power is being applied. Verify that at least one chas-
sis power supply module is installed in the chassis and func-
tioning normally.
CPU FAIL
Front
panel
Red
On
solid
CPU is unable to load the software from FLASH to RAM for
operation. As soon as possible, remove the Model 3096RC
from the CPCI chassis, wait 30 seconds, then re-insert the
Model 3096RC into the CPCI chassis and see if the problem
disappears. If the CPU FAIL LED remains lit after the Model
3096RC completes the power-up cycle, contact Patton Technical
Support to determine if the T-DAC needs to be replaced.
Off
The CPU is operating normally. No action recommended.
ALARM
Front
panel
Red
On
solid
A minor alarm condition has been detected.
Flash-
ing
A major alarm condition has been detected.
Off
The Model 3096RC is operating normally. No action rec-
ommended.
SYSTEM
Front
panel
Green
Flash-
ing
The Model 3096RC is operating normally. No action rec-
ommended.
Off
The Model 3096RC is not functioning properly. As soon
as possible, unplug both power cables from the Model
3096RC, wait 30 seconds, then plug the cables back
into the Mode 3096RC to see if the problem disappears.
If the SYSTEM LED remains lit after the Model 3096RC
completes the power-up cycle, contact Patton Technical
Support to determine whether the T-DAC needs to be
replaced.