Using a browser to complete Model 3096RC configuration
54
Model 3096RC T-DAC Getting Started Guide
3 • Configuring the T-DAC for operation
14. Under desired state, select dataMode(1).
15. Click the
Submit
button at the bottom of the page.
16. Repeat steps 9 through 15 for G.SHDSL modem port 16.
You have completed the configuration for example 3.
Example 4
Mapping between different blades. Connect WAN port 1, time slot 1 on Blade Number 1 to WAN port 7, time slot
31 on Blade Number 3.
Solution:
Complete the following steps.
1. Go to blade number 1.
2. Under Dev Type A, select t1-e1(1).
3. Under Dev Num A select port1(1).
4. Under Dev Slots A, enter 1.
5. Under Dev Type B, select to H110(5).
6. Under Dev Num B, select port1(1).
7. Under Dev Slots B, enter 1.
8. Under Dev Type B, bottom window, select from H110(6).
9. Under Dev Num B, bottom window, select port2(2).
10. Under Dev Slots B, bottom window, enter 1.
11. Click on
Submit Query
.
12. Go to blade number 3.
13. Under Dev Type A, select t1-e1(1).
14. Under Dev Num A, select port7(7).
15. Under Dev Slots A, enter 31.
16. Under Dev Type B, select to H110(5).
17. Under Dev Num B, select port2(2).
18. Under Dev Slots B, enter 1.
19. Under Dev Type B, bottom window, select from H110(6).
20. Under Dev Num B, bottom window, select port1(1).
21. Under Dev Slots B, bottom window, enter 1.
22. Click on
Submit Query
.
23. You have completed the configuration for example 4.