![background image](http://html1.mh-extra.com/html/patton-electronics/29xx-series/29xx-series_administrators-reference-manual_4056829156.webp)
Ethernet Main Window
156
Access Server Administrators’ Reference Guide
12 • Ethernet
Note
Note that the speed settings indicated above could indicate that the device
reached this speed duplex as a result of an auto-negotiated link, or from
being forced into this link state.
PrimaryIPAddress (boxEtherAPrimaryIpAddress)
The Primary ethernet IP address.
PrimaryIpMask (boxEtherAPrimaryIpMask)
The primary ethernet IP subnet mask.
PrimaryIpFilters (boxEtherAPrimaryIpFilters)
Filters packets based on the filters assigned to the Primary IP address of the Ethernet port. Enter the Filter ID
of a filter configured under Filter IP. Separate multiple filters using a comma (,).
SecondaryIpAddress (boxEtherASecondaryIpAddress)
The secondary ethernet IP address.
Note
This address is not propagated via RIP.
SecondaryIpMask (boxEtherASecondaryIpMask)
The secondary IP ethernet IP subnet mask.
SecondaryIpFilters (boxEtherASecondaryIpFilters)
Filters packets based on the filters assigned to the Secondary IP address of the Ethernet port. Enter the Filter
ID of a filter configured under Filter IP. Separate multiple filters using a comma (,).
Note
Only outbound filters can be applied to the secondary Ethernet. Inbound fil-
ters for the secondary Ethernet must be entered in the Primary IP Filter field.
Technique (boxEtherATechnique)
Turns ethernet port off and on. The remote access server must be reset for this setting to take effect.
•
disable(0)—ethernet port is disabled
•
static(1)—ethernet port is turned on. IP address(es) and mask(s) are obtained from data entered under the
Ethernet
link.
Config
Indicates the specified fixed rate and duplex for the Ethernet interface.
•
auto(0)-- auto-negotiate the settings for the interface (default)
•
100M_full(1)-- force the interface to 100M & full duplex
•
100M_half(2)-- force the interface to 100M & half duplex
•
10M_full(3)-- force the interface to 10M & full duplex
•
10M_half(4)-- force the interface to 100M & half duplex
Содержание 29XX Series
Страница 8: ...Contents Access Server Administrators Reference Guide 8...
Страница 19: ...19 Chapter 3 Import Export Chapter contents Introduction 20 Export Configuration 20 Import Configuration 22...
Страница 171: ...171 Access Server Administrators Reference Guide 14 Frame Relay Congestion frameEnableCongestion 177...
Страница 295: ...295 Chapter 25 Contacting Patton Chapter contents Introduction 296 Patton Electronics Company contact information 296...
Страница 304: ...304 Appendix B MIB trees Chapter contents Model 2960 MIB Tree Structure 305...
Страница 305: ...Model 2960 MIB Tree Structure 305 Access Server Administrators Reference Guide B MIB trees Model 2960 MIB Tree Structure...