![background image](http://html1.mh-extra.com/html/patton-electronics/29xx-series/29xx-series_administrators-reference-manual_4056829141.webp)
How Drop and Insert works
141
Access Server Administrators’ Reference Guide
10 • Drop and Insert
Figure 58. Drop and insert diagram
Note
This functionality can only be done on robbed bit lines. You can not per-
form drop and insert on a PRI line.
Using Drop and Insert
1.
Configure each WAN port doing drop and insert. Links 1 and 2 perform drop and insert together. Links 3
and 4 perform drop and insert together.
The line type/coding for all of the lines can be either D4/AMI or ESF/B8ZS
WAN A can have the following types of line signalling:
–
EMWinkStart
–
GroundStart
–
LoopStart
–
EMImmediate
WAN B and x on PBX must be configured identically.
WAN B can have the following types of line signalling:
–
EMWinkStart
–
EMImmediateStart
2.
Set the Desired Function for each channel on WAN A and B to dropInsert(7) (using channel assignment
under the T1/E1 link that is going to be performing drop and insert). The channels on WAN A selected
for drop and insert must match the channels on WAN B selected for drop and insert.
Note
We do not send digits with the EMWinkStart signalling. What this means is
that you can not direct the inbound call to a specific extension on the PBX.
Содержание 29XX Series
Страница 8: ...Contents Access Server Administrators Reference Guide 8...
Страница 19: ...19 Chapter 3 Import Export Chapter contents Introduction 20 Export Configuration 20 Import Configuration 22...
Страница 171: ...171 Access Server Administrators Reference Guide 14 Frame Relay Congestion frameEnableCongestion 177...
Страница 295: ...295 Chapter 25 Contacting Patton Chapter contents Introduction 296 Patton Electronics Company contact information 296...
Страница 304: ...304 Appendix B MIB trees Chapter contents Model 2960 MIB Tree Structure 305...
Страница 305: ...Model 2960 MIB Tree Structure 305 Access Server Administrators Reference Guide B MIB trees Model 2960 MIB Tree Structure...