![background image](http://html1.mh-extra.com/html/patton-electronics/29xx-series/29xx-series_administrators-reference-manual_4056829042.webp)
Modify Static User
42
Access Server Administrators’ Reference Guide
5 • Authentication
•
admin—Not currently implemented.
•
monitor—Not currently implemented.
•
rlogin—Causes the access server to rlogin into another host. See
“Service IP (suServiceIP)”
on page 43 for
information on configuring the remote host IP addresss.
•
telnet—Causes the access server to telnet into another host.
•
tcpraw—All 8 bits are passed unchecked and unaltered.
•
ppp—Access server will try to negotiate a PPP session.
•
cppp—Access server will try to negotiate a Compressed-PPP session.
Note
If a user attempts to login in using a different service than the one he or she
has been provided, the access server will reject the user. The exception to this
is CPPP which will revert to PPP if CPPP is not available on the client.
•
slip—Access server will negotiate a SLIP connection. Not currently implemented.
•
cslip—Access server will negotiate a Compressed-SLIP connection. Not currently implemented.
•
dialout—Access server will give a dialout connection. The dialout connection is an AT command set driven
connection into one of the access server modems. On line help is provided by typing
at help <cr>
.
•
vpn—This option is currently not supported.
Note
If a user attempts to login in using a different service than the one he or she
has been provided, the access server will reject the user. The exception to this
is CPPP which will revert to PPP if CPPP is not available on the client.
Note
All changes made to the running configuration must be saved to FLASH by
selecting
Record Current Configuration
under
Immediate Actions
on the
HOME
page of the access server. Failure to do so will cause all configuration
information to be lost the next time the access server is re-booted.
After the user information has been entered, click
Submit
.
Modify Static User
To modify or further configure the user, click the username you just created to display the
Static User
window
(see
figure 19
). Refer to the following sections while modifying the Static User settings. When you are finished,
click
Submit
to store the changes.
Содержание 29XX Series
Страница 8: ...Contents Access Server Administrators Reference Guide 8...
Страница 19: ...19 Chapter 3 Import Export Chapter contents Introduction 20 Export Configuration 20 Import Configuration 22...
Страница 171: ...171 Access Server Administrators Reference Guide 14 Frame Relay Congestion frameEnableCongestion 177...
Страница 295: ...295 Chapter 25 Contacting Patton Chapter contents Introduction 296 Patton Electronics Company contact information 296...
Страница 304: ...304 Appendix B MIB trees Chapter contents Model 2960 MIB Tree Structure 305...
Страница 305: ...Model 2960 MIB Tree Structure 305 Access Server Administrators Reference Guide B MIB trees Model 2960 MIB Tree Structure...