![background image](http://html1.mh-extra.com/html/patton-electronics/29xx-series/29xx-series_administrators-reference-manual_4056829070.webp)
Dial In Modify default window
70
Access Server Administrators’ Reference Guide
7 • Dial In
Modify Attempts
This portion of the Dial In Modify default window (see
figure 28
) describes modifying the login attempts
parameters for dial in users.
Figure 28. Dial In Modify window (modify Attempts, Configuration, and Maximum Time objects)
Failure Banner (diFailureBanner)
This defines a message of up to 254 characters in length that will be displayed to a user if authentication fails.
This message only appears when the authentication technique is Text.
Success Banner (diSuccessBanner)
The string sent to the dial-in window after a text login is authenticated successfully. The string can contain any
printable characters with the exception of the excape character (\). The following special sequences are recog-
nized and will be replaced before being sent to the customer:
•
\r
— carriage return
•
\n
—replaced with a new line
•
\t
—replaced by a tab
•
\M
—replaced by the MTU (maximum transfer unit)
•
\I
—replaced by the IP address assigned to the connection
Содержание 29XX Series
Страница 8: ...Contents Access Server Administrators Reference Guide 8...
Страница 19: ...19 Chapter 3 Import Export Chapter contents Introduction 20 Export Configuration 20 Import Configuration 22...
Страница 171: ...171 Access Server Administrators Reference Guide 14 Frame Relay Congestion frameEnableCongestion 177...
Страница 295: ...295 Chapter 25 Contacting Patton Chapter contents Introduction 296 Patton Electronics Company contact information 296...
Страница 304: ...304 Appendix B MIB trees Chapter contents Model 2960 MIB Tree Structure 305...
Страница 305: ...Model 2960 MIB Tree Structure 305 Access Server Administrators Reference Guide B MIB trees Model 2960 MIB Tree Structure...