background image

GP-M230-BX-010A 

2300 / IO 210 Manual 

    RD: June 2006 

R.L. 10A 

KH 

Some Authorities do not allow certain warranty exclusions or limitations on how long a warranty lasts or the exclusions or limita-
tions of incidental or consequential damages.  In such cases, the above limitations or exclusions may not apply to you and are not 
intended to do so where prohibited by law.  This warranty gives you specific legal rights.  You may also have other rights which 
vary by each jurisdiction. 

 
                                                              5285 BRADCO BLVD.    MISSISSAUGA, ON,    L4W 2A6 
                                                              2 SCHWANK WAY, WAYNESBORO,  GEORGIA.  30830-8336 
 

SCHWANK                        Ph: 905-712-4766      Fax: 905-712-8336 
INFRASAVE                     Ph: 1-866– INFRASV (463 7278)    Fax: 1-866-724 –9265 

LIMITED WARRANTY CERTIFICATE 

GAS-FIRED INFRA-RED PATIO HEATERS : 2300 / IO 210 SERIES 

 

The Manufacturer warrants that this product is free from defects in material or workmanship under normal use and service subject to 
the terms of this document. 
 

ONE YEAR WARRANTY

 

Subject to the conditions and limitations stated herein, during the term of this limited warranty, we will supply any component part 
(at our option a new or repaired component part) of the heater, as defined below, excluding any labor, which the Manufacturer’s ex-
amination determines to be defective in workmanship or material for a period of one year (1 year) from the date of installation, 
unless otherwise specified below. This warranty applies to the heater’s original owner, and subsequent transferees and only if the 
unit is installed and operated in accordance with the printed instructions accompanying the unit and in compliance with all applica-
ble installation, building codes and good trade practices. 

 

BURNER AND CERAMIC TILE - THREE YEAR WARRANTY 

The manufacturer warrants the burner and ceramic tile for a period of three years. (3 years) 

 

WHAT IS NOT COVERED 

The Manufacturer shall not be responsible for any expenses, including service, labor, diagnosis, analysis, material or transportation 
charges incurred during removal or reinstallation of this product, or any of its components or parts.  All labor or service charges shall 
be paid by the owner.  This warranty does not cover heating products improperly installed, misused, exposed to or damaged by neg-
ligence, accident, corrosive or contaminating atmosphere, water, excessive thermal shock, impact, abrasion, normal wear due to use, 
alteration or operation contrary to the owner’s manual or if the serial number has been altered, defaced or removed.  This warranty 
shall not apply if the input to the heating product exceeds by more than 2% of the rated input on the rating plate.  The Manufacturer 
shall not be liable for any default or delay in performance by its warranty caused by any contingency beyond its control, including 
war, government restrictions, or restraints, strikes, fire, flood, acts of God, or short or reduced supply of raw materials or products.

 

 

WARRANTY PROCEDURE

 

To establish the installation date for any purpose under this Limited Warranty, you must retain the original records that can establish 
the installation date of your unit. If you do not provide such documents, the start date of the term of this Limited Warranty will be 
based upon  the date of unit manufacture, plus thirty (30) days. Failure to maintain the equipment through regular annual service 
maintenance by a qualified service technician shall void the warranty. 

 

LIMITATIONS AND EXCLUSIONS 

This document contains all warranties made by the Manufacturer and may not be varied, altered or extended by any person.  There 
are no promises, or agreements extending from the Manufacture other than the statements contained herein.  THIS WARRANTY IS 
IN LIEU OF ALL WARRANTIES EXPRESSED OR IMPLIED, TO THE EXTENT AUTHORIZED BY THE LAWS OF THE  
JURISDICTION, INCLUDING SPECIFICALLY THE WARRANTIES OR MERCHANTIBILITY OF FITNESS FOR A PAR-
TICULAR PURPOSE. 
It is understood and agreed that the Manufacturer’s obligation hereunder is limited to repairing or replacing parts determined to be 
defective as stated above. In no event shall the Manufacturer be responsible for any alleged personal injuries or other special, inci-
dental or consequential damages. As to property damages, contract, tort or other claim the Manufacturer’s responsibility shall not 
exceed the purchase priced paid for the product. 
All replacement parts will be warranted  for the unused portion of the warranty coverage period remaining on the applicable unit. 

GP-D230-BX-03B 

2300 / IO 210 WARRANTY  

March 2006 

RL: 3B 

KH 

Содержание 2300 series

Страница 1: ...in the vicinity of this or any other appliance If you smell Gas Shut off gas to the appliance Extinguish any open flames Don t touch electrical switches Call your Gas supplier immediately FIELD CONVER...

Страница 2: ...d Infrasave 5285 Bradco Boulevard Mississauga Ontario L4W 2A6 Phone 1 866 INFRASV 463 7278 Fax 905 712 8336 e mail info infrasave com Waynesboro Georgia USA 30830 Customer Service Phone 706 554 6191 F...

Страница 3: ...8 3 MOUNTING OPTIONS 6 8 4 MINIMUM CLEARANCES TO COMBUSTABLES 11 8 5 SUGGESTED MOUNTING DISTANCES 12 2300 IO 210 SERIES INFRA RED PORTABLE PATIO HEATER FOR OUTDOOR AND NON RESIDENTIAL INDOOR SPACES T...

Страница 4: ...s equipment It is imperative that control compartment burners and circulating air passageways be kept clean and unobstructed Warning Due to the effects of radiant heat upon certain materials it is not...

Страница 5: ...s All piping joints should be tested for leaks with a soap and water solution Page 1 Series 2300 IO 210 Heaters are approved for both horizontal and angle mounting When angle mounting the short axis m...

Страница 6: ...er loads such as snow c Connect heater to the main gas line An approved 1 2 flexible connector available as an option from the manufacturer must be used to absorb gas line expansion and any vibration...

Страница 7: ...noxious fumes cause damage to the heater and will void the warranty Servicing of heater is essential for continued efficient operation Servicing should be carried out annually by qualified and licens...

Страница 8: ...n the upper bolt to allow the rotation of the mounting bracket and the heater 2 Remove the lower bolt securing the bracket and rotate the bracket up to the service position 3 Insert the bolt in the up...

Страница 9: ...0 VA and each consecutive heater will be sized at 20 VA The sum total will be the required Transformer size If total VA exceeds one size in between sizes se lect the next highest VA rating 8 2 MOUNTIN...

Страница 10: ...RACKET WITH GAS HOSE AND WIRING CHAIN HANGING SUPPORT SUPPLIED WITH HEATER POST MOUNTING BRACKET 8 3 MOUNTING OPTIONS FOR THE 2300 SERIES HIGH INTENSITY HEATERS CHAIN HANGING BRACKET SUPPLIED WITH HEA...

Страница 11: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH Diagram 4 2300 MOUNTING ARM TEMPLATE Page 7...

Страница 12: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH Diagram 5 2300 WALL BRACKET TEMPLATE Page 8...

Страница 13: ...ter using four nuts 4 Install the heater bracket to the wall mount bracket and remove the chains from the top of the heater NOTE The heater should be installed with enough slack on the wiring and a fl...

Страница 14: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH Page 10 Diagram 7 SERVICING HEATER...

Страница 15: ...213 N L INDOOR 6 10 5 14 5 14 5 2 5 26 17 2 5 28 2315 IO 215 N L OUTDOOR 16 8 13 5 10 2 21 12 5 2 24 5 2315 IO 215 N L INDOOR 17 11 19 16 5 3 28 5 18 5 3 30 Diagram 8 MOUNTING CLEARANCES 8 4 MINIMUM C...

Страница 16: ...eight to patio floor 6 6 6 6 7 0 7 0 8 0 8 0 C Side distance to patio edge 3 6 3 6 4 0 4 0 5 0 5 0 Y Side distance be tween heaters 6 0 6 0 8 0 8 0 10 0 10 0 W Distance to wall in front 6 0 7 0 7 0 8...

Страница 17: ...riod After a 5 minute complete shut off period has expired the heater may be reset manually from the Thermostat Page 13 9 ELECTRICAL REQUIREMENTS AND THERMOSTAT CONTROL All electrical installations mu...

Страница 18: ...RD June 2006 R L 10A KH 11 WIRING DIAGRAM FOR 2300 IO 210 SERIES with Honeywell S87C DSI Control See page 18 for FENWAL control wiring If installing remote control JP 1234 RK refer to wiring diagram i...

Страница 19: ...rom lockout is 1 5 uAmps microamps The output of the flame sensing circuit cannot be checked directly on the S87C Control body The flame sensing circuit current can be checked by bridging the flame se...

Страница 20: ...FROM DSI IGNITION CONTROL TO GAS VALVE RE PLACE WIRES IF NECESSARY PERFORM IGNITION LEAD TEST DESCRIBED IN SPARK IGNITION CIRCUIT CHECK DSI MODULE IGNITION POST FOR DEFECTS SPARK IGNITER MAY BE OUT O...

Страница 21: ...APPEARS NORMAL AT THE TIME CHECK FOR PROPER TEMPERATURE CONTROLLER OPERATION CHECK SENSOR FLAME SIGNAL WITH METER FOR 1 5uA MINIMUM STEADY READING REPEAT ABOVE CALL FOR HEAT ENDS SYSTEM SHUTS OFF TROU...

Страница 22: ...Ground V1 Valve Power V2 Valve Ground NC Alarm S1 Remote Flame Sensor Fenwal Control Terminal Designation Error Mode LED Indication Internal Control Failure Steady on Flame with No Call for heat 2 fl...

Страница 23: ...ng the thermostat or re moving 24 volts for a period of 5 seconds If the thermostat is still calling for heat after one hour the control will automatically reset and attempt to ignite the burner again...

Страница 24: ...y to the ignition control GND terminal DO NOT remove the existing ground lead Slowly move the other end of the jumper wire toward the stud terminal on the ignition control to establish a spark 2 Pull...

Страница 25: ...TO ENSURE THAT SITE CONDITIONS ARE COMPATIBLE WITH THIS HEATER AND TO ALLEVIATE NUISANCE CALL BACKS FOR THE CONTRACTOR THE FOLLOWING START UP NEEDS TO BE COMPLETED BY THE LICENSED GAS INSTALLER A CON...

Страница 26: ...EATER WAS FIELD TEST FIRED WITHOUT ANY MALFUNCTION YES NO INLET GAS SUPPLY PRESSURE WITH HEATER OPERATING WC GAS VALVE OUTLET Manifold PRESSURE WITH HEATER OPERATING WC HAS THE WIRING POLARITY BEEN MA...

Страница 27: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH 18 Replacement Parts List Only the following illustrated parts are available For any other parts please contact the manufacturer Page 23...

Страница 28: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH...

Страница 29: ...cts improperlyinstalled misused exposed to or damaged by neg ligence accident corrosive or contaminating atmosphere water excessive thermal shock impact abrasion normal wear due to use alteration or o...