                     TO BE COMPLETED BY THE LICENSED INSTALLER:                                 

PATIO HEATER COMMISSIONING REPORT    

TYPE OF GAS:  

NG 

LP  

IS HEATER EXPOSED TO CHEMICAL OR CORROSIVE ATMOSPHERE:

YES

NO

IS AN OPEN FLAME COMPATIBLE WITH THE INSTALLED LOCATION:

YES

NO

MINIMUM CLEARANCES CONFORM AS  PER I&O MANUAL:

YES

NO

IF THIS IS A HIGH ALTITUDE AREA WHAT IS THE ALTITUDE ABOVE SEA LEVEL

IS HEATER SHORT AXIS HORIZONTAL WITH THE VENTURI ON TOP:

YES

NO

IS GAS SUPPLY LINE ADEQUATELY SIZED FOR SYSTEM VOLUME: 

YES

NO

HAVE GAS LINES AND BRANCHES BEEN PURGED OF AIR: 

YES

NO

THIS HEATER WAS FIELD TEST FIRED WITHOUT ANY MALFUNCTION:

YES

NO

INLET GAS SUPPLY PRESSURE WITH HEATER OPERATING:

WC"

GAS VALVE OUTLET (Manifold) PRESSURE WITH HEATER OPERATING:

WC"

HAS THE WIRING POLARITY BEEN MAINTAINED THROUGHOUT:

YES

NO

WHAT IS THE VOLTAGE READING AT THE IGNITION MODULE:

VOLTS

WHAT IS THE FLAME SIGNAL STRENGTH IN uA FROM SENSOR:

uA (microamps)

IS THE HEATER CONTROLLED BY A THERMOSTAT:

YES

NO

IS THE THERMOSTAT STRATEGICALY LOCATED: 

YES

NO

TOTAL HEATERS SUPPLIED FROM ONE SINGLE TRANSFORMER:

TOTAL

WHAT IS THE RATING OF THE TRANSFORMER IN VA:

V.A.

WHAT IS THE TOTAL LENGTH OF THE LOW VOLTAGE WIRING:

FEET

WHAT IS THE GAUGE OF THE LOW VOLTAGE WIRING:

GAUGE

DOES THE HEATER HAVE GOOD ELECTRICAL GROUNDING:

YES

NO

* FAX COMPLETED FORM TO TECHNICAL SERVICES: CANADA - 905-712-8336  USA - 706-554-9390    

                Feet

Содержание 2300 series

Страница 1: ...in the vicinity of this or any other appliance If you smell Gas Shut off gas to the appliance Extinguish any open flames Don t touch electrical switches Call your Gas supplier immediately FIELD CONVER...

Страница 2: ...d Infrasave 5285 Bradco Boulevard Mississauga Ontario L4W 2A6 Phone 1 866 INFRASV 463 7278 Fax 905 712 8336 e mail info infrasave com Waynesboro Georgia USA 30830 Customer Service Phone 706 554 6191 F...

Страница 3: ...8 3 MOUNTING OPTIONS 6 8 4 MINIMUM CLEARANCES TO COMBUSTABLES 11 8 5 SUGGESTED MOUNTING DISTANCES 12 2300 IO 210 SERIES INFRA RED PORTABLE PATIO HEATER FOR OUTDOOR AND NON RESIDENTIAL INDOOR SPACES T...

Страница 4: ...s equipment It is imperative that control compartment burners and circulating air passageways be kept clean and unobstructed Warning Due to the effects of radiant heat upon certain materials it is not...

Страница 5: ...s All piping joints should be tested for leaks with a soap and water solution Page 1 Series 2300 IO 210 Heaters are approved for both horizontal and angle mounting When angle mounting the short axis m...

Страница 6: ...er loads such as snow c Connect heater to the main gas line An approved 1 2 flexible connector available as an option from the manufacturer must be used to absorb gas line expansion and any vibration...

Страница 7: ...noxious fumes cause damage to the heater and will void the warranty Servicing of heater is essential for continued efficient operation Servicing should be carried out annually by qualified and licens...

Страница 8: ...n the upper bolt to allow the rotation of the mounting bracket and the heater 2 Remove the lower bolt securing the bracket and rotate the bracket up to the service position 3 Insert the bolt in the up...

Страница 9: ...0 VA and each consecutive heater will be sized at 20 VA The sum total will be the required Transformer size If total VA exceeds one size in between sizes se lect the next highest VA rating 8 2 MOUNTIN...

Страница 10: ...RACKET WITH GAS HOSE AND WIRING CHAIN HANGING SUPPORT SUPPLIED WITH HEATER POST MOUNTING BRACKET 8 3 MOUNTING OPTIONS FOR THE 2300 SERIES HIGH INTENSITY HEATERS CHAIN HANGING BRACKET SUPPLIED WITH HEA...

Страница 11: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH Diagram 4 2300 MOUNTING ARM TEMPLATE Page 7...

Страница 12: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH Diagram 5 2300 WALL BRACKET TEMPLATE Page 8...

Страница 13: ...ter using four nuts 4 Install the heater bracket to the wall mount bracket and remove the chains from the top of the heater NOTE The heater should be installed with enough slack on the wiring and a fl...

Страница 14: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH Page 10 Diagram 7 SERVICING HEATER...

Страница 15: ...213 N L INDOOR 6 10 5 14 5 14 5 2 5 26 17 2 5 28 2315 IO 215 N L OUTDOOR 16 8 13 5 10 2 21 12 5 2 24 5 2315 IO 215 N L INDOOR 17 11 19 16 5 3 28 5 18 5 3 30 Diagram 8 MOUNTING CLEARANCES 8 4 MINIMUM C...

Страница 16: ...eight to patio floor 6 6 6 6 7 0 7 0 8 0 8 0 C Side distance to patio edge 3 6 3 6 4 0 4 0 5 0 5 0 Y Side distance be tween heaters 6 0 6 0 8 0 8 0 10 0 10 0 W Distance to wall in front 6 0 7 0 7 0 8...

Страница 17: ...riod After a 5 minute complete shut off period has expired the heater may be reset manually from the Thermostat Page 13 9 ELECTRICAL REQUIREMENTS AND THERMOSTAT CONTROL All electrical installations mu...

Страница 18: ...RD June 2006 R L 10A KH 11 WIRING DIAGRAM FOR 2300 IO 210 SERIES with Honeywell S87C DSI Control See page 18 for FENWAL control wiring If installing remote control JP 1234 RK refer to wiring diagram i...

Страница 19: ...rom lockout is 1 5 uAmps microamps The output of the flame sensing circuit cannot be checked directly on the S87C Control body The flame sensing circuit current can be checked by bridging the flame se...

Страница 20: ...FROM DSI IGNITION CONTROL TO GAS VALVE RE PLACE WIRES IF NECESSARY PERFORM IGNITION LEAD TEST DESCRIBED IN SPARK IGNITION CIRCUIT CHECK DSI MODULE IGNITION POST FOR DEFECTS SPARK IGNITER MAY BE OUT O...

Страница 21: ...APPEARS NORMAL AT THE TIME CHECK FOR PROPER TEMPERATURE CONTROLLER OPERATION CHECK SENSOR FLAME SIGNAL WITH METER FOR 1 5uA MINIMUM STEADY READING REPEAT ABOVE CALL FOR HEAT ENDS SYSTEM SHUTS OFF TROU...

Страница 22: ...Ground V1 Valve Power V2 Valve Ground NC Alarm S1 Remote Flame Sensor Fenwal Control Terminal Designation Error Mode LED Indication Internal Control Failure Steady on Flame with No Call for heat 2 fl...

Страница 23: ...ng the thermostat or re moving 24 volts for a period of 5 seconds If the thermostat is still calling for heat after one hour the control will automatically reset and attempt to ignite the burner again...

Страница 24: ...y to the ignition control GND terminal DO NOT remove the existing ground lead Slowly move the other end of the jumper wire toward the stud terminal on the ignition control to establish a spark 2 Pull...

Страница 25: ...TO ENSURE THAT SITE CONDITIONS ARE COMPATIBLE WITH THIS HEATER AND TO ALLEVIATE NUISANCE CALL BACKS FOR THE CONTRACTOR THE FOLLOWING START UP NEEDS TO BE COMPLETED BY THE LICENSED GAS INSTALLER A CON...

Страница 26: ...EATER WAS FIELD TEST FIRED WITHOUT ANY MALFUNCTION YES NO INLET GAS SUPPLY PRESSURE WITH HEATER OPERATING WC GAS VALVE OUTLET Manifold PRESSURE WITH HEATER OPERATING WC HAS THE WIRING POLARITY BEEN MA...

Страница 27: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH 18 Replacement Parts List Only the following illustrated parts are available For any other parts please contact the manufacturer Page 23...

Страница 28: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH...

Страница 29: ...cts improperlyinstalled misused exposed to or damaged by neg ligence accident corrosive or contaminating atmosphere water excessive thermal shock impact abrasion normal wear due to use alteration or o...

Отзывы: