10. SEQUENCE OF OPERATION: HONEYWELL S87C DSI CONTROL 

(See page 19 for FENWAL Control) 

1. On A call for heat the S87C DSI Control will check for a false flame condition or short to 

ground. The module will lock out if a false flame condition is present. (Reset is usually done 
manually from the   Thermostat). 

2. Spark (30,000volts) is generated at the Spark Ignition Stud, for direct ignition of the main 

Burner by the single Spark  Igniter. 

3. Main Gas Control Valve is powered and OPENS lighting off the Main Burner. 
4. Seperate Flame Sensor, relays the presence of Main Burner flame back to the DSI Control by 

a rectified dc voltage signal. (TFI period) 

5. If this dc signal is a minimum of 1.5ua (microamps) the flame remains established and the 

DSI Control discontinues the ignition spark. 

6. This is the 21 second T.F.I  (Trial For Ignition)  period where flame has to be established 

first, and confirmed with a minimum signal strength of 1.5 uAmps(microamps) back to the 
DSI Control. Failing this the DSI will go into a Safety Lockout Mode and shut down the 
Burner. (Reset is manually done from the Thermostat). 

7. On a loss of power the S87 allows the system to shut down safely. Start up is initiated when 

power is restored 

8.   On a loss of  Main Burner flame, the timed T.F.I. is repeated. Safety Lock-out occurs if the 

flame is not re-established within the T.F.I period. After a 5 minute complete shut off period 
has expired, the heater may be reset manually from the Thermostat.   

Page 13 

9.  ELECTRICAL REQUIREMENTS AND THERMOSTAT CONTROL 

All electrical installations must meet local and the latest edition Electrical Code PART 1 CSA 
C22.1 in Canada and ANSI/NFPA N0 70 in the U.S.A.. Single heater requires 24 Volt, 60 Hz 
electrical transformer sized at 40 VA. If multiple heaters are connected to a single transformer, 
the proper transformer is 24 Volt, 60 Hz, sized at 40 VA for the first heater, and 30 VA each for 
all subsequent additional heaters. For example, four heaters wired together (parallel), require a 
transformer of 150 VA. It is recommended to install at most 2 heaters per zone for best comfort 
control and economy of operation. PROPER WIRING POLARITY MUST BE MAINTAINED, 
particularly when grouping the heaters in a zone.

 

Total wiring distances of up to 200' must use minimum 16 gauge electrical wire, and wiring dis-
tances of over 200' must use minimum 14 gauge electrical wire. The heater must be electrically 
grounded in accordance with the local 
electrical code. Malfunction of the heating system will result if the voltage varies by more than 
+10% or -10%.

 

The heater can be controlled by a line moisture proof thermostat “off-on” switch, or Remote 
Control. Total load of all heaters must be considered in determining the required contact rating 
of the controlling thermostat or switch. 

9.1.  REMOTE CONTROL 

Patio Heaters can be operated with Remote Control Option; JP-1234-RK and handset JP-1234-
HS. Refer to the manual accompanying the remote control for installation. 

Содержание 2300 series

Страница 1: ...in the vicinity of this or any other appliance If you smell Gas Shut off gas to the appliance Extinguish any open flames Don t touch electrical switches Call your Gas supplier immediately FIELD CONVER...

Страница 2: ...d Infrasave 5285 Bradco Boulevard Mississauga Ontario L4W 2A6 Phone 1 866 INFRASV 463 7278 Fax 905 712 8336 e mail info infrasave com Waynesboro Georgia USA 30830 Customer Service Phone 706 554 6191 F...

Страница 3: ...8 3 MOUNTING OPTIONS 6 8 4 MINIMUM CLEARANCES TO COMBUSTABLES 11 8 5 SUGGESTED MOUNTING DISTANCES 12 2300 IO 210 SERIES INFRA RED PORTABLE PATIO HEATER FOR OUTDOOR AND NON RESIDENTIAL INDOOR SPACES T...

Страница 4: ...s equipment It is imperative that control compartment burners and circulating air passageways be kept clean and unobstructed Warning Due to the effects of radiant heat upon certain materials it is not...

Страница 5: ...s All piping joints should be tested for leaks with a soap and water solution Page 1 Series 2300 IO 210 Heaters are approved for both horizontal and angle mounting When angle mounting the short axis m...

Страница 6: ...er loads such as snow c Connect heater to the main gas line An approved 1 2 flexible connector available as an option from the manufacturer must be used to absorb gas line expansion and any vibration...

Страница 7: ...noxious fumes cause damage to the heater and will void the warranty Servicing of heater is essential for continued efficient operation Servicing should be carried out annually by qualified and licens...

Страница 8: ...n the upper bolt to allow the rotation of the mounting bracket and the heater 2 Remove the lower bolt securing the bracket and rotate the bracket up to the service position 3 Insert the bolt in the up...

Страница 9: ...0 VA and each consecutive heater will be sized at 20 VA The sum total will be the required Transformer size If total VA exceeds one size in between sizes se lect the next highest VA rating 8 2 MOUNTIN...

Страница 10: ...RACKET WITH GAS HOSE AND WIRING CHAIN HANGING SUPPORT SUPPLIED WITH HEATER POST MOUNTING BRACKET 8 3 MOUNTING OPTIONS FOR THE 2300 SERIES HIGH INTENSITY HEATERS CHAIN HANGING BRACKET SUPPLIED WITH HEA...

Страница 11: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH Diagram 4 2300 MOUNTING ARM TEMPLATE Page 7...

Страница 12: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH Diagram 5 2300 WALL BRACKET TEMPLATE Page 8...

Страница 13: ...ter using four nuts 4 Install the heater bracket to the wall mount bracket and remove the chains from the top of the heater NOTE The heater should be installed with enough slack on the wiring and a fl...

Страница 14: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH Page 10 Diagram 7 SERVICING HEATER...

Страница 15: ...213 N L INDOOR 6 10 5 14 5 14 5 2 5 26 17 2 5 28 2315 IO 215 N L OUTDOOR 16 8 13 5 10 2 21 12 5 2 24 5 2315 IO 215 N L INDOOR 17 11 19 16 5 3 28 5 18 5 3 30 Diagram 8 MOUNTING CLEARANCES 8 4 MINIMUM C...

Страница 16: ...eight to patio floor 6 6 6 6 7 0 7 0 8 0 8 0 C Side distance to patio edge 3 6 3 6 4 0 4 0 5 0 5 0 Y Side distance be tween heaters 6 0 6 0 8 0 8 0 10 0 10 0 W Distance to wall in front 6 0 7 0 7 0 8...

Страница 17: ...riod After a 5 minute complete shut off period has expired the heater may be reset manually from the Thermostat Page 13 9 ELECTRICAL REQUIREMENTS AND THERMOSTAT CONTROL All electrical installations mu...

Страница 18: ...RD June 2006 R L 10A KH 11 WIRING DIAGRAM FOR 2300 IO 210 SERIES with Honeywell S87C DSI Control See page 18 for FENWAL control wiring If installing remote control JP 1234 RK refer to wiring diagram i...

Страница 19: ...rom lockout is 1 5 uAmps microamps The output of the flame sensing circuit cannot be checked directly on the S87C Control body The flame sensing circuit current can be checked by bridging the flame se...

Страница 20: ...FROM DSI IGNITION CONTROL TO GAS VALVE RE PLACE WIRES IF NECESSARY PERFORM IGNITION LEAD TEST DESCRIBED IN SPARK IGNITION CIRCUIT CHECK DSI MODULE IGNITION POST FOR DEFECTS SPARK IGNITER MAY BE OUT O...

Страница 21: ...APPEARS NORMAL AT THE TIME CHECK FOR PROPER TEMPERATURE CONTROLLER OPERATION CHECK SENSOR FLAME SIGNAL WITH METER FOR 1 5uA MINIMUM STEADY READING REPEAT ABOVE CALL FOR HEAT ENDS SYSTEM SHUTS OFF TROU...

Страница 22: ...Ground V1 Valve Power V2 Valve Ground NC Alarm S1 Remote Flame Sensor Fenwal Control Terminal Designation Error Mode LED Indication Internal Control Failure Steady on Flame with No Call for heat 2 fl...

Страница 23: ...ng the thermostat or re moving 24 volts for a period of 5 seconds If the thermostat is still calling for heat after one hour the control will automatically reset and attempt to ignite the burner again...

Страница 24: ...y to the ignition control GND terminal DO NOT remove the existing ground lead Slowly move the other end of the jumper wire toward the stud terminal on the ignition control to establish a spark 2 Pull...

Страница 25: ...TO ENSURE THAT SITE CONDITIONS ARE COMPATIBLE WITH THIS HEATER AND TO ALLEVIATE NUISANCE CALL BACKS FOR THE CONTRACTOR THE FOLLOWING START UP NEEDS TO BE COMPLETED BY THE LICENSED GAS INSTALLER A CON...

Страница 26: ...EATER WAS FIELD TEST FIRED WITHOUT ANY MALFUNCTION YES NO INLET GAS SUPPLY PRESSURE WITH HEATER OPERATING WC GAS VALVE OUTLET Manifold PRESSURE WITH HEATER OPERATING WC HAS THE WIRING POLARITY BEEN MA...

Страница 27: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH 18 Replacement Parts List Only the following illustrated parts are available For any other parts please contact the manufacturer Page 23...

Страница 28: ...GP M230 BX 010A 2300 IO 210 Manual RD June 2006 R L 10A KH...

Страница 29: ...cts improperlyinstalled misused exposed to or damaged by neg ligence accident corrosive or contaminating atmosphere water excessive thermal shock impact abrasion normal wear due to use alteration or o...

Отзывы: