background image

31

SFC Dust Collector Bill of Materials

Item 

Part No. 

Description 

 

Filter (Consult Parker) 

02-10019-0001 

QuickSeal Filter Access Door Assembly

 

02-10019-0002 

High Temp QuickSeal Filter Access Door Assembly

 

02-10019-0003 

QuickSeal Filter Access Door Assembly, Exp Type

2A 

42-10002-0001 

External Filter Door Seal Gasket

 

42-10002-0003 

High Temp External Filter Door Seal Gasket

2B 

42-10005-0001 

Internal Filter Door Seal Gasket

 

42-10005-0002 

High Temp Internal Filter Door Seal Gasket

2C 

10-10079-0001 

Door Panel

2D 

10-10143-0001 

Door Rod

2E 

10-10193-0001 

Stainless Steel Door Rod End Caps

2F 

39-10002-0001 

Handle Grip

2G 

39-10003-0001 

 Door  Handle

 

Inlet Collar (Consult Parker)

07-10002-0001 

Diaphragm Valve

4A 

07-10003-0001 

Diaphragm Valve Repair Kit

 

Compressed Air Manifold (Consult Parker)

20-10076-00XX 

Solenoid Enclosure (Consult Parker)

6A 

20-10076-RPR 

Solenoid Repair Kit

6B 

20-10076-RPLC 

Solenoid Valve Replacement

45-0237 

55-Gallon (208 Liter) Drum

7A 

45-10024-0020 

20-Gallon (76 Liter) Drum

45-10034-0055 

55 Gallon Drum Lid

8A 

45-10034-0020 

20 Gallon Drum Lid

45-10022-0055 

55 Gallon Quick Release Collar

9A 

45-10022-0020 

20 Gallon Drum Quick Release Collar

10 

15-0233 

14” Hose Clamp

11 

15-0202 

14” Flexible Duct

12 

18-0944 

14” Adapter Plate

13 

02-6041 

14” Slide Gate

14 

12-10011 

Rupture Panel, Dome 36X36

 

12-10012 

Rupture Panel, Dome 12X18

 

12-10013 

Rupture Panel, Dome 18X35

 

02-10586-0001 

Asm, Explosion Vent, 45x28

 

02-10618-0001 

Asm, Explosion Vent, 32x19

 

02-10618-0002 

Asm, Explosion Vent, 16x19

 

12-10007-3636 

Rupture Panel, Flat, 36x36 (Pre Oct 2012)

 

12-10006-1618 

Rupture Panel, Flat, 16x18 (Pre Oct 2012)

 

12-10001-1836 

Rupture Panel, Flat, 18x36 (Pre Oct 2012)

15 

10-11358-0001 

Clip, Fmd, Exp Vent, 45x28

 

10-11358-0002 

Clip, Fmd, Exp Vent, 14 GA, 32x19

 

10-11358-0003 

Clip, Fmd, Exp Vent, 16 GA, 16x19

16 

12-10005-3636 

Weather Cover, Rupture Panel, 36x36

 

12-10005-1836 

Weather Cover, Rupture Panel, 18x36

 

12-10005-1618 

Weather Cover, Rupture Panel, 16x18

 

12- 10008- 1619  

Weather Cover, Top Mount, 16x19

 

12- 10008- 1932  

Weather Cover, Top Mount, 19x32

 

12- 10008- 2845 

Weather Cover, Top Mount, 28x45

 

12- 10014- 1218  

Weather Cover, Top Mount, 12x18

 

12- 10014- 1835 

Weather Cover, Top Mount, 18x35

17 

10-11392-0001 

Weather Cover, Side Mount, 45x28

 

10-11602-0004 

Weather Cover, Side Mount, 32x19

 

10-11602-0002 

Weather Cover, Side Mount, 16x18

Содержание SFC

Страница 1: ...Downward Flow Cartridge Dust Collector Owner s Manual Model SFC...

Страница 2: ...Parker Parker Order _________________________________________________________________ Unit Model ___________________________________________________________________ Unit Serial ______________________...

Страница 3: ...odule Sections applies to 4 or more modules 6 3 4 Electrical Installation 11 3 4 1 Mounting the Controls 11 3 4 2 Solenoid Valve Enclosure Wiring 11 3 4 3 Heater Wiring 15 3 5 Compressed Air Connectio...

Страница 4: ...Dust Removal 24 5 3 Servicing the Compressed Air Components 24 5 4 Servicing the Direct Drive Blower and Motor System 24 5 5 Servicing Cartridge Media 25 5 6 Servicing Optional Return Air Safety Filt...

Страница 5: ...t collector The unit should be inspected frequently and dirt removed to prevent excessive accumulation which may result in flash over or fire damage The SFC system should not be used to support person...

Страница 6: ...nt should be by a licensed contractor that is also experienced in potential fire and explosion hazards and adheres to related local state and federal codes standards laws and regulations Parker is not...

Страница 7: ...v Page intentionally left blank...

Страница 8: ...ding in non traffic areas even though the dust collector is equipped with an explosion vent 2 Introduction Thank you for selecting Parker dust collection equipment to assist you in your commitment to...

Страница 9: ...nism provides brief bursts of compressed air directed through the diaphragm valves toward the cartridge filter This pulsing action dislodges the collected particles from the media where they fall into...

Страница 10: ...crating strapping and hold down bolts Locate all hardware bags sealant and other assembly materials provided with your unit 3 Installation 3 1 Off Loading and Inspection SFC dust collector modules are...

Страница 11: ...4 FIGURE 2 SFC Typical SINGLE UNIT Installation Diagram PARKER PARKER 44 10335 0001...

Страница 12: ...5 FIGURE 3 Recommended Unit Clearances 44 10337 0001...

Страница 13: ...hopper and filter module together Securely tighten all hardware at the filter module and hopper Recheck leg assembly sway braces to ensure they are tight Install fasteners bolt flat washer lock washer...

Страница 14: ...7 FIGURE 4 Single Hopper SFC 44 10309 0001...

Страница 15: ...8 FIGURE 5 Multiple Hopper SFC 44 10309 0002...

Страница 16: ...9 FIGURE 6 Multiple Hopper SFC 44 10309 0003...

Страница 17: ...10 FIGURE 7 Multiple Modules SFC 44 10310 0001...

Страница 18: ...pulse cleaning Motor starter with Digital Pulse Control DPC for on demand pulse cleaning VFD with DPM for continuous pulse cleaning VFD with DPC for on demand pulse cleaning Refer to Parker sales orde...

Страница 19: ...12 FIGURE 8 SFC Pressure Gauge Installation 44 10333 0001 Rev A...

Страница 20: ...13 FIGURE 9 Solenoid Wiring to Pulse Controls for 2 3 4 and 5 Tier Units...

Страница 21: ...14 FIGURE 10 Pneumatic Valve Assembly 44 10332 0001...

Страница 22: ...l compressed air supply pipe fittings and connections 3 6 Assembly of Optional Equipment 3 6 1 Blower Purge Package Installation TIP OVER HAZARD Anchor dust collector to concrete pad prior to install...

Страница 23: ...16 FIGURE 11 Legs Support Top Mount Blower 44 10331 0001 NOTE FOR BLOWERS 20 HP OR LARGER SUPPORT LEGS ARE REQUIRED TO BE INSTALLED UNDER THE CLEAN AIR PLENUM...

Страница 24: ...17 FIGURE 12 Abrasive Inlet Installation 44 10338 0001...

Страница 25: ...ry air lock Do not allow any object to be placed in or near the rotary air lock during operation Verify rotary air lock rotation matches rotation arrows affixed to assembly 3 6 4 Abrasive Inlet Instal...

Страница 26: ...s not designed for dust storage The slide gate should remain open during normal operation 3 6 6 Inlet Cover and Blank Cover Plate Installation Inlet collar and blank cover plates bolt directly to the...

Страница 27: ...20 FIGURE 16 EDAP Interconnection FIGURE 15 EDAP Installation 48 10007...

Страница 28: ...transport an assembled 5 high unit due to height restrictions within the vehicle When shipping this unit it will be necessary to ship the EDAP separately This will require the customer to assemble th...

Страница 29: ...interchange at motor junction box Engage starter disconnect switch start blower and recheck rotation NOTE Proper blower rotation is required to move the designed amount of air A blower rotating in the...

Страница 30: ...23 FIGURE 17 SFC Series Door Filter Installation 44 10329 0001...

Страница 31: ...timerboard to the Continuous Clean position Or if the system is sup plied with DPC Pulse Control place the Continuous Clean PS switch on the timerboard to PS position The MOT AUX terminals at the time...

Страница 32: ...ace prior to being closed A flat solid section of door handle will be visible when door assembly is in the properly closed position Refer to Figure 17 If cam surface of the door handle is visible Quic...

Страница 33: ...for HEPA filters TABLE 2 Cartridge Filters CARTRIDGE FILTER PARKER PART NUMBER GENERAL DESCRIPTION OF FILTER MEDIA ProTura Nanofiber 33 10089 ProTura Nanofiber layer on cellulose ProTura Nanofiber FR...

Страница 34: ...l This may require bending panel sections away from the frame for frame removal Care should be taken to avoid sharp panel edges during this activity 4 Dispose of the removed rupture panel in accordanc...

Страница 35: ...proper motor starter overload rating against full load amps on motor name plate Adjust or replace overloads as required Ensure drum is properly sealed against drum lid package Ensure drum lid package...

Страница 36: ...ge to the timer board and voltage output from timer boards to solenoid valves Consult DPM DPC Pulse Control Panel Installation and Operation Manual for additional assistance Reduce high set point on D...

Страница 37: ...30 7 Illustrated Parts FIGURE 21 SFC Series 44 10330 0001 FIGURE 22 SFC Series Explosion Vents...

Страница 38: ...0020 20 Gallon Drum Lid 9 45 10022 0055 55 Gallon Quick Release Collar 9A 45 10022 0020 20 Gallon Drum Quick Release Collar 10 15 0233 14 Hose Clamp 11 15 0202 14 Flexible Duct 12 18 0944 14 Adapter...

Страница 39: ...32 Page intentionally left blank...

Страница 40: ...or misuse misapplication or normal wear and tear e Equipment not properly installed operated and maintained under normal conditions and recommended applications As Buyers exclusive remedy for any def...

Страница 41: ...shooting effort details 5 Description of physical location and or environment details The Buyer shall cooperate with PARKER in its investigation and provide full information and documentation concerni...

Страница 42: ...arker com dhfns Hiross Zander Essen Germany 49 2054 9340 www parker com hzfd Padova Italy 39 049 9712 111 www parker com hzfd Engine Filtration Water Purification Racor Dewsbury England 44 0 1924 487...

Отзывы: