24
PWDXXA-40X_20 5715-677 UK.indd 26.01.17
Electronic for proportional DC valves
Series PWDXXA-40X
Operation Manual
Parker Hannifin Corporation
Hydraulics Group
Parker Hannifin Corporation
Hydraulics Group
Parameter overview for expert mode
Parameter
Description
Unit
Parameter range
Default
setting
from
up to
P5
dither amplitude
%
0
10.0
0
P6
dither frequncy
Hz
0
300
0
P9
quiescent current channel A
%
0
25.0
0
P10
quiescent current channel B
%
0
25.0
0
P13
bypass gain
–
0
100.0
0
P14
T-portion PT1-element
–
0
100.0
0
P16
P-portion
–
0
100.0
0
P17
I-portion
–
0
100.0
0
P18
D-portion
–
-100.0
+100.0
0
P19
T-portion DT1-element
–
0
100.0
0
P20
feedback scaling
%
0
200.0
100.0
P21
comparator function window
%
0
200.0
0
P23
comparator rise delay time
ms
0
10000
0
P24
comparator turn-off delay time
ms
0
10000
0
P26
window I-portion
-
0
200.0
20.0
P27
reduct. window I-portion
-
0
100.0
100.0
E2
closed loop control
–
0 = inactive (open loop)
0 = inaktiv
1 = active (int. closed loop)
2 = active (ext. closed loop)
E11
position transducer type
–
1 = ±10 V
1 = ±10 V
2 = ±20 mA
3 = 4-20 mA bipolar
4 = D1FC/WLL NG06
5 = D3FC/WLL NG10
6 = RLL NG06
7 = D31FS
8 = D41FS
9 = D81FS
10 = D91FS
11 = D111FS
12 = 4-20 mA unipolar
13 = TEL 50/70
14 = TEL 90/125
E12
cable break detection
feedback
–
0
voltage: 0
0 = voltage
current ±20 mA: 0
current 4-20 mA: 1
E25
MIN operating threshold
–
0 = 1 %
1 = 0.01 %
0 = 1 %
IA
solenoid current channel A
–
1 = 3.5 A
2 = 2.7 A
4 = 1.3 A
4 = 1.3 A
IB
solenoid current channel B
–
1 = 3.5 A
2 = 2.7 A
4 = 1.3 A
4 = 1.3 A
J2
Compability mode
–
0 = off (fast)
0 = off
1 = on (Design <20)
E81
Function
–
0 = Sensor supply
0
"Sensor supply" pin
1 = Comparator out
Содержание PWD Series
Страница 38: ......