Series PWDXXA-40X
Operation Manual
PWDXXA-40X_20 5715-677 UK.indd 26.01.17
Parker Hannifin Corporation
Hydraulics Group
Parker Hannifin Corporation
Hydraulics Group
Individual description of expert parameters
P5
dither amplitude
Adjustment of dither amplitude.
To reduce the influence of solenoid friction.
P6
dither frequency
Adjustment of dither frequency.
To match the dither signal to the valve dynamic.
P9
initial current channel A
Adjustment of the bias current for the solenoid of the valve side A.
To compensate for the solenoid initial current.
P10
initial current channel B
Adjustment of the bias current for the solenoid of the valve side B.
To compensate for the solenoid initial current.
P13
bypass gain
Adjustment of the bypass gain for the controller.
To improve the control dynamic.
P14
T-portion of PT1
Adjustment of the integral action time for the PT1-portion of the controller.
To attenuate for the P-portion.
P16
P-portion
Adjustment of the P-portion for the controller.
For the basic tuning of the controller.
P17
I-portion
Adjustment of the I-portion for the controller.
To reduce the control failure.
P18
D-portion
Adjustment of the D-portion for the controller.
To improve the control dynamic.
P19
T-portion of DT1
Adjustment of the pre-hold time for the DT1-portion of the controller.
To attenuate for the D-portion.
P20
feedback scaling
Adjustment of the scaling factor for the feedback signal.
To match the feedback signal span to the operating range.
P21
window for
comparator function
Adjustment of the comparator window for the feedback monitoring.
To adjust the feedback monitoring range.
P23
comparator rise
delay time
Adjustment of the comparator rise delay time.
To delay the rise threshold for the comparator function.
P24
comparator turn-off
delay time
Adjustment of the comparator turn-off delay time.
To delay the turn-off threshold for the comparator function.
P26
window for I-gain
activation
Adjustment of the I-portion active range in terms of the control difference.
To limit the I-portion on a certain range.
P27
I-gain window reduction
Adjustment of the I-portion outside the window in terms of the control difference.
To match the response behaviour to the I-portion.
E2
control mode
Adjustment of the operating mode for the controller.
To select the control function.
E11
type of feedback device
Adjustment of the feedback device type.
To match the feedback input to the signal device features.
E12
cable break
detection feedback
Adjustment of the operating mode for the feedback cable break detection.
To turn on resp. off of the cable break detection for the feedback signal.
E25
MIN operating
threshold
Adjustment of the MIN operating threshold.
To match the response sensitivity for the MIN-stroke step.
IA
nominal current
solenoid A
Adjustment of the maximum current for the solenoid of the valve side A.
To match the solenoid output to the nominal current of the solenoid.
IB
nominal current
solenoid B
Adjustment of the maximum current for the solenoid of the valve side B.
To match the solenoid output to the nominal current of the solenoid.
J2
Compability mode
Adjustment of the control cycle.
To adapt the cycle time to design version <20.
E81
Funktion
"Sensor supply" pin
Adjustment of the "Sensor supply" pin.
To select the function sensor supply or comparator out.