34
PWDXXA-40X_20 5715-677 UK.indd 26.01.17
Electronic for proportional DC valves
Series PWDXXA-40X
Operation Manual
Parker Hannifin Corporation
Hydraulics Group
Parker Hannifin Corporation
Hydraulics Group
Failure message
Description/corrective action
The Com Port is not available!
Terminate the other program, or quit the message and select another
RS-232C port via the menu “Options > Port”. Afterwards reconnect
the null modem cable.
Unable to open COM port
Com port is not available. Quit the message and select another
RS-232C port via the menu “Options > Port”. Afterwards reconnect
the null modem cable.
There is no module connected or
the communication is disturbed!
No data exchange possible. Either the electronics has been removed,
the port is mismatched, or the connection will be disturbed by strong
electrical fields. Check if the Com port is set for “9600, 8, 1. none,
none” via the menu “Options > Port”.
Wrong password!
Retype the password, notice the exact spelling (case sensitivity).
Wrong input!
An unvalid character or a value outside the permitted range has
been used at parameter entry.
Keep the entered parameters?
During parameter loading from the electronics module memory
the preset parameters from the left hand screen display may be
rejected or maintained.
The chosen module isn´t the
same as the connected hardware!
In principle, parameters dedicated to a type which deviates from
the connected electronics module may be edited. However, for data
transmitting the correct module has to be connected. If parameters
will be loaded from a module which deviates from the selected
one, the parameters from the left hand side screen display of the
program will be overwritten.
file name.pxd already exists.
Do you want to replace the file?
The file name already exists within the indicated directory. Select
another name, another directory or overwrite the existing file with “OK”.
Failure messages and corrective actions
5.6. Error messages
Malfunctions when using the ProPxD software program will be indicated via appropriate failure mes-
sages.
Содержание PWD Series