Appendix C – Regulatory Compliance: UL and CE
91
DRIVE I/O
MO
T
OR FEEDB
A
CK
Twisted at 3 twists
minimum per
inch (25 mm)
R clamp braid to
heatsink; make loop
as short as possible
GEM-VM50
Breakout Module
(enclosure mounted, or
not accessible to user)
RS-232/485
Cable
Drive I/O Cable
Motor Feedback
Cable
Motor
Cable
GV-H20n
Drive
HPC
Motor
VDC+
VDC–
+24VDC
Power
Supply
Varistor
(3 places; for
single phase, see
previous drawing)
Earth
VAC
Saddle clamp to bottom
for mechanical strain
relief, if desired
Mains
Filter
Mains
Filter
GV-
H20n
L1
L2
L3
Bond braid to earthed panel.
Use R-clamp or bulkhead
clamshell clamp. (See
360
°
bonding drawing.)
I/O
Limits
Ferrite
absorber
detail
Wrap wires
through ferrite
two times.
Protective
earth
Ferrite
absorber
Mount to earthed
metal panel. Remove
paint from flange and
mounting locations.
Remove paint
from flange and
mounting locations.
EMC Installation – GV-H20n
www.comoso.com