Introduction
Single axis devices
14
192-120102 N16 December 2010
2.7
Conditions of utilization for CE-conform operation
In diesem Kapitel finden Sie
Conditions of utilization mains filter .................................................................................. 14
Conditions of utilization for cables / motor filter ................................................................ 15
Additional conditions of utilization .................................................................................... 15
- Industry and trade -
The EC guidelines for electromagnetic compatibility 2004/108/EC and for electrical
operating devices for utilization within certain voltage limits 2006/95/EC are fulfilled
when the following boundary conditions are observed:
Operation of the devices only in the condition in which they were delivered,
i.e. with all housing panels.
In order to ensure contact protection, all mating plugs must be present on the
device connections even if they are not wired.
Please respect the specifications of the manual, especially the technical
characteristics (mains connection, circuit breakers, output data, ambient
conditions,...).
2.7.1.
Conditions of utilization mains filter
A mains filter is required in the mains input line if the motor cable exceeds a certain
length. Filtering can be provided centrally at the system mains input or separately
for each device.
Use of the devices in a commercial and residential area (limit value class in
accordance with EN 61800-3)
The following mains filters are available for independent utilization:
Device:
Compax3S
Limit value
class
Motor cable length
Mains filter
Order No.:
S0xxV2
C2
< 10 m
without
C2
> 10 m, < 100 m
NFI01/01
S1xxV2,
S0xxV4, S150V4
C2
< 10 m
without
C2
> 10 m, < 100 m
NFI01/02
S300V4
C3
< 10 m
without
C2, C3
> 10 m, < 100 m
NFI01/03
Connection length: Connection between mains filter and device:
unshielded: < 0.5 m
shielded
< 5 (fully shielded on ground - e.g. ground of control cabinet)
Mains filter: