Forming the capacitors
Forming the capacitors only required with 400VAC axis controllers and PSUP
mains module
If the device was stored longer than one year, the intermediate capacitors must be
re-formed!
Forming sequence:
Remove all electric connections
Supply the device with 230VAC single phase for 30 minutes
via the L1 and L2 terminals on the device or
multi axis devices via L1 and L2 on the PSUP mains module
2.6
Warranty conditions
The device must not be opened.
Do not make any modifications to the device, except for those described in the
manual.
Make connections to the inputs, outputs and interfaces only in the manner
described in the manual.
Fix the devices according to the
mounting instructions
(see on page 32).
We cannot provide any guarantee for other mounting methods.
Note on exchange of options
Device options must be exchanged in the factory to ensure hardware and software
compatibility.
When installing the device, make sure the heat dissipators of the device receive
sufficient air and respect the recommended mounting distances of the devices
with integrated ventilator fans in order to ensure free circulation of the cooling air.
Make sure that the mounting plate is not exposed to external temperature
influences.
Please note in the
event of storage >1
year: