Compax3
device description
Single axis devices
26
192-120102 N16 December 2010
3.3.6.
Compax3Sxxx V4
In diesem Kapitel finden Sie
Power supply connector X1 for 3AC 400VAC/480VAC-C3S devices ............................... 26
Braking resistor / high voltage supply connector X2 for 3AC 400VAC/480VAC_C3S devices
....................................................................................................................................... 27
Connection of the power voltage of 2 C3S 3AC devices .................................................. 27
3.3.6.1
Power supply connector X1 for 3AC 400VAC/480VAC-
C3S devices
By cyclically switching on and off the power voltage, the input current
limitation can be overloaded, which will cause a device error.
Therefore please wait at least 2 minutes after switching off before you switch
the device on again!
PIN
Designation
1
L1
2
L2
3
L3
4
PE
Mains connection Compax3SxxxV4 3AC
Controller type
S015V4
S038V4
S075V4
S150V4
S300V4
Supply voltage
Three phase 3*400VAC/480VAC
80-528VAC / 50-60Hz
Input current
3Aeff
6Arms
10Arms
16Arms
22Arms
Maximum fuse rating per
device(=short circuit
rating)
6A
10A
16A
20A
25A
MCB miniature circuit breaker, K characteristic
D*
* for UL conform operation, a miniatu
re circuit breaker, K characteristic, Type S203
is to be used.
The 3AC V4 devices must only be operated with three phases!
Caution - Risk of Electric Shock!
Always switch devices off before wiring them!
Dangerous voltages are still present until 10 min. after switching off the power
supply.
Device protection
Caution!