- 24 - Aries User Guide
Power Supply
Input Power
The mains motor power supply and control power supply for the Aries Drive
must meet the following requirements.
Model
Requirements
Motor Input Power
AR-01xx, AR-02xx, AR-04xx,
AR-08xx, AR-13xx
(L1, L2)
120/240 VAC, 50/60 Hz, single phase
AR-20xE
(L1, L2, L3)
240 VAC, 50/60 Hz, single phase or
three phase
AR-30xE
(L1, L2, L3)
240 VAC, 50/60 Hz, three phase
only
Control Input Power
All models
(C1, C2)
120/240 VAC, single phase
Figure 15 Input Power Requirements
Mains/Input Power Connector
AR-01xx, AR-02xx,AR-04xx, AR-08xx, AR-13xx
Connector Type....................................... Removable screw terminal
Terminals ........................................7
Pitch ................... 0.200 in (5.08 mm)
Wire Range ....................12-26 AWG
.......................................14-27 SWG
................................(0.12-3.30 mm
2
)
Wire Strip length .. 0.31 in (7.87 mm)
Torque....7.0 in–lbs nom. (0.79 N-m)
AR-20xE, AR-30xE
Connector Type.......................................
Non-Removable
screw terminal
Terminals ......................................10
Pitch ........................ 0.315 in (8 mm)
Wire Range ....................10-22 AWG
.......................................12-23 SWG
....................................(0.5-4.0 mm
2
)
Wire Strip length .... 0.25 in (6.5 mm)
Torque....7.0 in–lbs nom. (0.79 N-m)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com