- 130 - Aries User Guide
TCI
Transfer Commanded Current
Type
Transfer
Product Rev
Syntax
<a_>TCI
Aries 1.0
Units
Amps
Range
N/A
Default
N/A
Response
TCI: <*>5.ØØ
See Also
DMTIC
,
DMTICD
,
DMTIP
,
TDICNT
,
TDIMAX
The
TCI
command reports the commanded motor current in amps (peak of
sine).
TDHRS
Transfer Operating Hours
Type
Transfer
Product Rev
Syntax
<a_>TDHRS
Aries 1.0
Units
Lifetime operating hours
(resolution is hours)
Range
Hour counter rolls over at 536854528 hours
Default
N/A
Response
TDHRS: <*>16
See Also
RESET
,
TERRLG
The
TDHRS
command reports the lifetime number of hours that the Aries
drive has had power applied (AC mains or Control power).
TDICNT
Transfer Continuous Current Rating
Type
Transfer
Product Rev
Syntax
<a_>TDICNT
Aries 1.0
Units
Amps rms
Range
Drive Dependant
Default
N/A
Response
TDICNT: <*>1Ø
See Also
DMTIC
,
DMTICD
,
DMTIP
,
TCI
,
TDIMAX
The
TDICNT
command reports the continuous current rating of the drive in
amps rms
.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com