- 114 - Aries User Guide
................................................................ MPMxxxxxxxxJLxx: ERES10000
................................................................ MPMxxxxxxxxJPxx: ERES12000
................................................................ MPMxxxxxxxxJQxx: ERES20000
................................................................ MPMxxxxxxxxJTxx: ERES24000
................................................................ MPMxxxxxxxxJXxx: ERES4096
................................................................ MPMxxxxxxxxJYxx: ERES8192
................................................................ MPMxxxxxxxxJZxx: ERES16384
Note:
Motors with the Smart Encoder option set ERES automatically.
Changing the ERES value may cause unpredictable motor responses.
Note:
ERES is fixed at 4096 for Aries drives with Resolver option.
Daedal Positioning Tables (encoder options)
-E2........................................................... ERES42000
-E3........................................................... ERES84000
-E4........................................................... ERES420000
-E5...........................................................ERES8400
For linear servo motors, use the following equation to determine the proper
ERES
, based on both the encoder resolution and the motor’s electrical (or
magnetic) pitch (
DMEPIT
).
)
(
_
)
(
count
mm
resolution
Encoder
mm
DMEPIT
ERES
=
Example
Linear encoder resolution (post quad) is 1
µ
m and the electrical pitch is 42
mm (
DMEPIT42
).
ERES
is calculated as:
42000
)
(
10
1
)
(
42
3
-
=
⋅
=
count
mm
mm
ERES
ERROR
Error-Checking Report-Back
Type
Error Handling
Product Rev
Syntax
<a_>ERROR
Aries 1.0
Units
N/A
Range
Default
N/A
Response
ERROR: <*>NO
ERRORS
See Also
none
The
ERROR
command gives a text-based status report of drive errors
(
E25
through
E46
) that currently prevent the drive from enabling.
To re-enable the drive correct the specified fault, then reset the drive or cycle
power to it.
Table 46 contains the possible errors appearing in the text-based report and
their descriptions.