Chapter 6 Command Reference - 139 -
TVER
Transfer Current Commanded Velocity Error
Type
Transfer
Product Rev
Syntax
<a_>TVER
Aries 2.0
Units
Revolutions per second or meters per second
Range
N/A
Default
N/A
Response
TVER: <*>
1.55
See Also
DMEPIT
,
DMVLIM, TVELA, TVEL
This command is only valid in
DMODE4
(velocity mode) and
DMODE6
or
DMODE7
(position mode).
In velocity mode (
DMODE4
),
TVEL
reports the commanded ±10V value from
the user before any internal limits are checked.
In position mode (
DMODE6-7
),
TVEL
reports the internal velocity command
and is limited by
DMVLIM
.