Chapter 6 Command Reference - 135 -
TPC
Transfer Position Commanded
Type
Transfer
Product Rev
Syntax
<a_>TPC
Aries 2.0
Units
Encoder counts
Range
-2147483648 to +2147483647
Default
N/A
Response
TPC: <*>
Ø
See Also
ERES, TPE, SMPER
This command is only valid in
DMODE4
(velocity mode) and
DMODE6
or
7
(position mode). This command allows you to display the
commanded
position
.
Note:
The reported value is measured in commanded counts (AKA: “motor
counts”).
TPE
Transfer Position of Encoder
Type
Transfer
Product Rev
Syntax
<a_>TPE
Aries 1.0
Units
Encoder counts
Range
-2147483648 to +2147483647
Default
N/A
Response
TPE: <*>
Ø
See Also
ERES, TPC, SMPER
The
TPE
command reports the present feedback device position, based on
the encoder resolution (
ERES
).
TPER
Transfer Position Error of Encoder
Type
Transfer
Product Rev
Syntax
<a_>TPER
Aries 2.0
Units
Encoder counts
Range
-2147483648 to +2147483647
Default
N/A
Response
TPER: <*>
Ø
See Also
ERES
,
INPOSDB
,
TPE
,
SMPER
This command is only valid in
DMODE6
or
7
(position mode).The
TPER
command reports the present position error. The error is reported in
feedback device counts and is based on the encoder resolution (
ERES
). The
position error is calculated every 62.5 µs.
Note:
When the drive is set to
DMODE6
or
DMODE7
, the position error is the
difference between the commanded position and the actual position read by
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com