Appendix B External Power-Dump Resistor Selection - 169 -
Drive
Capacitance
(uF)
V
TRIP
(VDC)
E
C
(120 VAC)
Joules
E
C
(240 VAC)
Joules
AR-01xx
440
400
28
9
AR-02xx
660
400
43
14
AR-04xx
880
400
57
19
AR-08xx
1100
400
72
24
AR-13xx
1590
400
104
35
AR-20xE
2240
400
N/A
50
AR-30xE
2240
400
N/A
50
When the voltage drops below 385 VDC, the Aries drive stops dissipating power through the
power dump resistor.
Table 59 Drive Capacitor Absorption
Energy Dissipated in Motor Winding Resistance
Some energy is dissipated in the motor windings. Because the energy is
converted to wasted heat in the motor, it is referred to as
copper losses
.
The energy during deceleration can be derived from the mass, deceleration
rate, motor resistance, and motor force constant. If some of the parameters
are not known, the energy dissipated in the motor windings (
E
W
) can
conservatively be assumed zero (0).
This is based on current and motor winding resistance.
(
)
D
M
D
F
L
F
D
M
W
t
R
t
k
v
M
M
t
R
I
E
⋅
⋅
⎟⎟
⎠
⎞
⎜⎜
⎝
⎛
⋅
⋅
+
⋅
=
⋅
=
2
2
2
1
2
1
Where
E
W
= energy dissipated in the motor windings (Joules) – copper losses
I
=
current through the windings (Amps
rms
)
R
M
= line to line motor resistance (Ohms)
t
D
=
deceleration time (Seconds)
M
F
= mass of forcer in kilograms (kg)
M
L
= mass of load in kilograms (kg)
k
F
=
motor force constant (N/Amp
rms
)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com