Parameter Reference
C-253
AC30 series Variable Speed Drive
1207 Favourites[18]
Same as PNO 1189
UINT
0000
0000 to 3145
ALWAYS
OPERATOR
02941
1208 Favourites[19]
Same as PNO 1189
UINT
0000
0000 to 3145
ALWAYS
OPERATOR
02943
1214 Automatic Pole Pairs
Parameters::Motor Control::Motor Nameplate
BOOL
TRUE
ALWAYS
TECHNICIAN 4
02955
1225 DST Active
Parameters::Device Manager::Real Time Clock
BOOL
FALSE
ALWAYS
OPERATOR
02977
1228 Time Zone Offset
Parameters::Device Manager::Real Time Clock
REAL
0.00
-14.00 to 14.00
ALWAYS
OPERATOR
02983
1229 Mechanical Offset
Parameters::System Board::SB Encoder
DINT
Min to Max
NEVER
ENGINEER
1,4
02985
1230 Motor Position
Parameters::System Board::SB Encoder
REAL
x.xx
-180.00 to 180.00
deg
NEVER
TECHNICIAN 1,4
02987
1231 Enc To Mot Shaft Ratio
Setup::Inputs and Outputs::SB Encoder
Parameters::System Board::SB Encoder
INT
1,
1 to 50
STOPPED TECHNICIAN 4
02989
1232 Encoder Status
Parameters::System Board::SB Encoder
USINT
(enum)
0:OK
1:SIN COS ISSUE
2:OK WITH COMMS WARNING
3:COMMS ERROR
4:CALIB IN PROGRESS
5:CALIB ERROR
6:NOT DETECTED
NEVER
TECHNICIAN 4
02991
1235 Endat Comms Status
Parameters::System Board::SB Encoder
USINT
(enum)
0:NOT SUPPORTED
1:WORKING
2:CHECKSUM
3:BIT WARNING
4:TIMEOUT
5:ERROR
NEVER
ENGINEER
4
02997
1239 Local Run Key Active
Parameters::Keypad::Local Control
BOOL
TRUE
ALWAYS
TECHNICIAN
03005
1240 Local Reverse
Parameters::Keypad::Local Control
BOOL
FALSE
ALWAYS
OPERATOR
1,4
03007
1241 Open Connections
Monitor::Communications::Base Modbus
Parameters::Base Comms::Modbus
USINT
0 to 255
NEVER
OPERATOR
03009
1246 Speed Loop Auto Set
Parameters::Motor Control::Spd Loop Settings
BOOL
TRUE
ALWAYS
TECHNICIAN 4
03019
1247 Ratio Load Mot Inert
Parameters::Motor Control::Spd Loop Settings
REAL
1.0
0.1 to 100.0
ALWAYS
TECHNICIAN 4
03021
1248 Speed Loop Bandwidth
Parameters::Motor Control::Spd Loop Settings
USINT
(enum)
1
0:LOW
1:MEDIUM
2:HIGH
ALWAYS
TECHNICIAN 4
03023
1251 CANopen Actual Baud
Monitor::Communications::Option
Parameters::Option Comms::CANopen
USINT
(enum)
Same as PNO 213
NEVER
OPERATOR
4
03029
1252 HV SMPS Up Time
Parameters::Device Manager::Runtime Statistics
UDINT
0 to Max
s
NEVER
TECHNICIAN 1
03031
1253 Local/Rem Key Active
Parameters::Keypad::Local Control
BOOL
TRUE
ALWAYS
TECHNICIAN
03033
1254 IO Option SW Version
Parameters::Device Manager::Drive info
WORD
NEVER
OPERATOR
4
03035
1255 Local Dir Key Active
Parameters::Keypad::Local Control
BOOL
TRUE
ALWAYS
TECHNICIAN
03037
1256 OEM ID
Parameters::Device Manager::Drive info
UINT
0 to 65535
NEVER
ENGINEER
03039
1257 Seq Stop Method SVC
Setup::Motor Control::Control and Type
Parameters::Motor Control::Ramp
USINT
(enum)
1
0:DISABLED VOLTAGE
1:RAMP
2:STOP RAMP
ALWAYS
TECHNICIAN 4
03041
1258 Stack Serial No
Parameters::Device Manager::Drive info
STRING[15]
NEVER
OPERATOR
03043
1264 Min Speed Clamp
Parameters::Motor Control::Speed Ref
REAL
-110.00
-110.00 to 0.00
%
ALWAYS
OPERATOR
03055
1265 Max Speed Clamp
Parameters::Motor Control::Speed Ref
REAL
110.00
0.00 to 110.00
%
ALWAYS
OPERATOR
03057
1266 Speed Trim
Parameters::Motor Control::Speed Ref
REAL
0.00
-300.00 to 300.00
%
ALWAYS
OPERATOR
03059
1267 Trim in Local
Parameters::Motor Control::Speed Ref
BOOL
FALSE
ALWAYS
OPERATOR
03061
1268 Random Pattern PMAC
Parameters::Motor Control::Pattern Generator
BOOL
FALSE
ALWAYS
ENGINEER
4
03063
1269 DHCP State
Parameters::Base Comms::Ethernet
DWORD
NEVER
ENGINEER
03065
1270 Monitor
Parameters::Device Manager::Soft Menus
ARRAY[0..19]
ALWAYS
OPERATOR
03067
1271 Monitor[0]
Monitor::Quick Monitor
Parameters::Device Manager::Soft Menus
UINT
0383
0000 to 3145
ALWAYS
OPERATOR
2
03069
1272 Monitor[1]
Same as PNO 1271
UINT
0393
0000 to 3145
ALWAYS
OPERATOR
2
03071
1273 Monitor[2]
Same as PNO 1271
UINT
0395
0000 to 3145
ALWAYS
OPERATOR
2
03073
1274 Monitor[3]
Same as PNO 1271
UINT
0696
0000 to 3145
ALWAYS
OPERATOR
2
03075
1275 Monitor[4]
Same as PNO 1271
UINT
0895
0000 to 3145
ALWAYS
OPERATOR
2
03077
1276 Monitor[5]
Same as PNO 1271
UINT
0926
0000 to 3145
ALWAYS
OPERATOR
2
03079
1277 Monitor[6]
Same as PNO 1271
UINT
0000
0000 to 3145
ALWAYS
OPERATOR
2
03081
1278 Monitor[7]
Same as PNO 1271
UINT
0000
0000 to 3145
ALWAYS
OPERATOR
2
03083
1279 Monitor[8]
Same as PNO 1271
UINT
0000
0000 to 3145
ALWAYS
OPERATOR
2
03085
1280 Monitor[9]
Same as PNO 1271
UINT
0000
0000 to 3145
ALWAYS
OPERATOR
2
03087
1281 Monitor[10]
Same as PNO 1271
UINT
0000
0000 to 3145
ALWAYS
OPERATOR
2
03089
1282 Monitor[11]
Same as PNO 1271
UINT
0000
0000 to 3145
ALWAYS
OPERATOR
2
03091
1283 Monitor[12]
Same as PNO 1271
UINT
0000
0000 to 3145
ALWAYS
OPERATOR
2
03093
1284 Monitor[13]
Same as PNO 1271
UINT
0000
0000 to 3145
ALWAYS
OPERATOR
2
03095
1285 Monitor[14]
Same as PNO 1271
UINT
0000
0000 to 3145
ALWAYS
OPERATOR
2
03097
1286 Monitor[15]
Same as PNO 1271
UINT
0000
0000 to 3145
ALWAYS
OPERATOR
2
03099
1287 Monitor[16]
Same as PNO 1271
UINT
0000
0000 to 3145
ALWAYS
OPERATOR
2
03101
1288 Monitor[17]
Same as PNO 1271
UINT
0000
0000 to 3145
ALWAYS
OPERATOR
2
03103
Содержание AC30 series
Страница 4: ...AC30 series Variable Speed Inverter...
Страница 17: ...Product Overview 3 3 AC30 series Variable Speed Inverter Functional Overview Block Diagram for Frames D E F...
Страница 18: ...3 4 Product Overview AC30 series Variable Speed Inverter Block Diagram for Frames G H J...
Страница 19: ...Product Overview 3 5 AC30 series Variable Speed Inverter Block Diagram for Frame K...
Страница 20: ...3 6 Product Overview AC30 series Variable Speed Inverter Block Diagram for Frames L N...
Страница 22: ...3 8 Product Overview AC30 series Variable Speed Inverter...
Страница 65: ...6 27 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Scoping Drive Parameters...
Страница 66: ...6 28 Setup Wizard AC30 series Variable Speed Inverter...
Страница 84: ...7 18 Trips Fault Finding AC30 series Variable Speed Inverter...
Страница 122: ...9 6 Fire Mode AC30 series Variable Speed Drive...
Страница 188: ...C 6 Parameter Reference AC30 series Variable Speed Drive...
Страница 189: ...Parameter Reference C 7 AC30 series Variable Speed Drive...
Страница 461: ...AC30 series Variable Speed Inverter...