Function
Code
Function Definition
Setting Range
Mfr’s Value Change
F316
DI1 terminal function
setting
0: No function
1: Run
2: Stop
3: Multi-stage speed 1
4: Multi-stage speed 2
5: Multi-stage speed 3
6: Multi-stage speed 4
7: Reset
8: Free stop (coast
stop)
9: External coast stop
10: Accel/decel hold
11: Forward run
jogging
12: Reverse run
jogging
13: Increase freq UP
14: Decrease freq
DOWN
15: “FWD” terminal
16: “REV” terminal
17: Three-line type
input “X” terminal
18: Accel/decel time
switchover 1
19-58 refer to product
manual for additional
settings
11
√
F317
DI2 terminal function
setting
9
√
F318
DI3 terminal function
setting
15
√
F319
DI4 terminal function
setting
16
√
F320
DI5 terminal function
setting
7
F321
DI6 terminal function
setting
8
F322
DI7 terminal function
setting
0
F323
DI8 terminal function
setting
0
√
F324
Free stop (coast
stop) terminal logic
0: Positive logic (low
level = True);
1: Negative logic
(high level = True)
0
X
F325
External coast stop
terminal logic
0
X
F326
Watchdog time
0.0-3000.0
10.0
√
F327
Stop mode
0: Free stop (coast
stop)
1: Decel to stop
0
X
F328
Terminal filter times
1-100
10
√
F329
Reserved
Parameter List and Default Settings
10-8
Содержание AC10 series
Страница 13: ...Dimensions 2 8 This page intentionally left blank...
Страница 15: ...Connections 2 10...
Страница 19: ...Panel Display IP20 Units 3 4 Items and Remarks Displayed on the Panel...
Страница 23: ...Menu Organization IP66 Units 3 8 Items and Remarks Displayed on the Panel...
Страница 33: ...The Default Applications 8 2 Application 1 Basic Speed Control...
Страница 34: ...8 3 The Default Applications Application 2 Auto Manual Control...
Страница 35: ...The Default Applications 8 4 Application 3 Preset Speeds...
Страница 36: ...8 5 The Default Applications Application 4 Raise Lower Trim...
Страница 37: ...The Default Applications 8 6 Application 5 PID...