F207
Frequency source selection
0: X;
1: X+Y;
2: X or Y (terminal
switchover);
3: X or X+Y (terminal
switchover);
4: Combination of
stage speed and
analog
5: X-Y
6: Reserved;
0
X
F208
Terminal operation mode
0: No function;
1: Two-line
operation mode 1;
2: Two-line
operation mode 2;
3: three-line
operation mode 1;
4: three-line
operation mode 2;
5: start/stop
controlled by
direction pulse
0
X
F209
Motor stopping mode
0: stop by
deceleration time;
1: free stop (coast
stop)
0
X
Function
Code
Function Definition
Setting Range
Mfr’s Value Change
10-5
Parameter List and Default Settings