![Parker AC10 series Скачать руководство пользователя страница 28](http://html2.mh-extra.com/html/parker/ac10-series/ac10-series_quick-start-manual_3765104028.webp)
Fault
Description
Causes
Possible Solution
CE
Communication
Timeout
* Communication fault
* PC/PLC does not send command at
fixed time
* Check communication line for
reliable connected
FL
Flycatching Fault
* Flycatching failure
* Track again
* Contact manufacturer
Note: No P.F1 protection for single-phase and three-phase under 5.5kW.
Only above 22kW inverters can trip into OC2
Malfunction
Items to Be Checked
Counter Measures
Motor not Running
Wiring correct?
Setting correct?
Too big with load?
Motor is damaged?
Malfunction protection occurs?
Get connected with power
Check wiring
Checking malfunction
Reduce load
Check against Table 10-1
Wrong Direction of Motor
Running
U, V, W wiring correct?
Parameters setting correct?
Correct wiring
Set the parameters correctly
Motor Turning but Speed
Change not Possible
Wiring correct for lines with given
frequency?
Correct setting of running mode?
Motor overloaded?
Correct wiring
Correct setting;
Reduce load
Motor Speed Too High or
Too Low
Motor’s rated value correct?
Drive ratio correct?
Inverter parameters are set
incorrectly?
Check if inverter output voltage is
abnormal?
Check motor nameplate data
Check the setting of drive ratio
Check parameters setting
Check V/HZ Characteristic value
Motor Running Unstable
Too big load?
Too big with load change?
Phase loss?
Motor malfunction.
Reduce load; reduce load change,
increase capacity
Correct wiring
Power Trip
Wiring current is too high?
Check input wring
Selecting matching air switch
Reduce load
Check inverter malfunction
5-3
Troubleshooting
Содержание AC10 series
Страница 13: ...Dimensions 2 8 This page intentionally left blank...
Страница 15: ...Connections 2 10...
Страница 19: ...Panel Display IP20 Units 3 4 Items and Remarks Displayed on the Panel...
Страница 23: ...Menu Organization IP66 Units 3 8 Items and Remarks Displayed on the Panel...
Страница 33: ...The Default Applications 8 2 Application 1 Basic Speed Control...
Страница 34: ...8 3 The Default Applications Application 2 Auto Manual Control...
Страница 35: ...The Default Applications 8 4 Application 3 Preset Speeds...
Страница 36: ...8 5 The Default Applications Application 4 Raise Lower Trim...
Страница 37: ...The Default Applications 8 6 Application 5 PID...