All the Alarms are shown on the screen at
the top, it is also shown if we have the
Sound activated, speaking 1 only notice
when the Alarm has triggered and with a
delay of about 7 - 9 seconds.
It will always show us all the Alarms on
the screen, that is, if we have 2 alarms it
will show us 2, if we have 7 alarms, it will
show us all 7 of them. Some recover and
others DO NOT.
1 - Revolutions per Minute (RPM) Alarm
This Alarm is programmable in the Configuration sec-
tion. We have configured 8500 RPM as standard value.
You have to adapt this configuration to your Engine, add
or remove.
A very practical alarm. For example, if we use the “PXP Meter” in flight, the Paramotor will
indicate if we have exceeded the maximum RPM advised by the manufacturer of our engine
and we can try different types of propellers. We also will always have the RPM controlled.
In the Configuration section, we advise to have or program (-100 / -150) below the maximum
RPM, that way we won’t always have the Alarm going off on values that are not interesting,
it will only alert when it reaches near the maximum of RPM,which is what concerns us. It’s
your decision.