Testing
5-6
7976-A2-GB20-10
August 1998
Send Remote Line Loopback
The local unit initiates this test by sending a line loopback up or down command
to the remote unit for 10 seconds. When the remote unit detects the loopback up
command, it puts itself in line loopback and lights the front panel test LED. The
remote unit remains in loopback until it receives a loopback down command or
the remote unit’s test timeout value is exceeded. The send line loopback tests
both units. External equipment can be used to verify the link.
CAP
G.703
Port
CAP
E1
LIU
Framer
Framer
Transceiver
98-16001
CAP
CAP
E1
LIU
Framer
Framer
Transceiver
AIS
Local
Remote
"
Procedure
To run a Remote Send Line loopback:
1. Position the cursor at the Up or Down selection next to Send Line Loopback
on the Network Tests screen.
2. Press the spacebar to select either Up or Down.
3. Position the cursor at the Send command next to Up or Down selection.
4. Press Enter.
The local unit stops sending the loopback command automatically after
10 seconds. You cannot stop the Send Remote Line Loopback test manually.
The Send Remote Line Loopback cannot be started when any other loopback or
a Send and Monitor 511 test is active on the network interface.
Содержание Hotwire 7976
Страница 42: ...Initial Startup and Configuration 3 18 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Страница 56: ...Monitoring the Unit 4 14 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Страница 66: ...Testing 5 10 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Страница 78: ...Security 7 6 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Страница 104: ...Standards Compliance for SNMP Traps B 6 7976 A2 GB20 10 August 1998...
Страница 112: ...Technical Specifications D 2 7976 A2 GB20 10 August 1998...