
Standards Compliance for SNMP Traps
B-5
7976-A2-GB20-10
August 1998
The tests that affect the enterpriseTestStart, enterpriseTestStop, and the
variable-bindings are different for each particular interface. Diagnostic tests are
only supported on the physical E1 network and user data port interfaces. The
specific tests and variable-bindings are described in the following table:
Interface
enterpriseTestStart/Stop
Variable-Bindings
Possible Cause
SDSL
Network
H
ifIndex (RFC 1573)
H
ifAdminStatus (RFC 1573)
H
ifOperStatus (RFC 1573)
H
ifType (RFC 1573)
H
ifTestType (RFC 1573)
The following objects control tests
in SNMP-managed devices:
– noTest – Stops the test in
progress.
– testLoopLLB – Initiates a Local
Loopback.
– testLoopPLB – Initiates a
Payload Loopback.
– testLoopRLB – Initiates a
Remote Loopback.
– testSendMon511 – Initiates a
Send and Monitor 511 test.
– testSendLLBUp – Initiates an
LLB Up message to the remote
unit.
– testSendLLBDown – Initiates an
LLB Down message to the
remote unit.
H
enterpriseTest Start – Any
one of the following tests is
active on the interface:
– Line Loopback
– Payload Loopback
– Repeater Loopback
– Remote Line Loopback
– Send and Monitor 511
H
enterpriseTest Stop – No tests
currently running on the
interface.
G.703
H
ifIndex (RFC 1573)
H
ifAdminStatus (RFC 1573)
H
ifOperStatus (RFC 1573)
H
ifTestType (RFC 1573)
The following objects control tests
in SNMP-managed devices:
– noTest – Stops the test in
progress.
– testLoopExternalDTE
Содержание Hotwire 7976
Страница 42: ...Initial Startup and Configuration 3 18 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Страница 56: ...Monitoring the Unit 4 14 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Страница 66: ...Testing 5 10 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Страница 78: ...Security 7 6 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Страница 104: ...Standards Compliance for SNMP Traps B 6 7976 A2 GB20 10 August 1998...
Страница 112: ...Technical Specifications D 2 7976 A2 GB20 10 August 1998...