Monitoring the Unit
4-11
7976-A2-GB20-10
August 1998
H
Status: Contains the contents of the status events register. The status events
register maintains a history of specific events that have occurred during an
interval. Values include:
— Y – Remote alarm indication signal received at the G.703 interface
— L – Loss of signal detected at the G.703 interface
— E – Excessive error rate threshold exceeded
— F – Frame synchronization bit error detected
— V – Line code violation detected
— None – No significant events have occurred
This Field . . .
Contains . . .
Current interval
timer
The number of seconds which have elapsed in the current
15-minute interval. Maximum value is 900 seconds (15 minutes).
This counter resets every 15 minutes.
Current Interval
Performance data for the current 15 minutes.
Interval
xx
Historical performance data for up to 96 15-minute intervals
(24 hours) where the value of
xx is from 01 to 96.
Error Events
Counter
A running total of CRC and OOF events. Total range = 0–65535.
Counter resets when the statistics are cleared.
Содержание Hotwire 7976
Страница 42: ...Initial Startup and Configuration 3 18 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Страница 56: ...Monitoring the Unit 4 14 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Страница 66: ...Testing 5 10 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Страница 78: ...Security 7 6 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Страница 104: ...Standards Compliance for SNMP Traps B 6 7976 A2 GB20 10 August 1998...
Страница 112: ...Technical Specifications D 2 7976 A2 GB20 10 August 1998...