KEY ACCESS PROGRAMMING
Programs features quickly, without entering addresses or section numbers.
To activate “key access programming”, press [
ENTER
], followed by installer, master or user code 1.
(Access code required depends on the feature you wish to access - see below.) Then press the key cor-
responding to the desired feature. Press [
ENTER
] or [
CLEAR
] to exit.
key
[8]
Installer test mode
(installer code only)
In installer test mode, a confirmation beep (intermittent) indicates test is "on", a "rejection" beep (long)
indicates test is "off". The bell will squawk during walk testing to indicate opened, functional zones.
[9]
"Auto arming" time program
(all 3 codes)
Key [9] flashes. Enter two digits (00 to 23) for hours, followed by 2 digits (00 to 59) for minutes.
[
MEM
]
"Panel time" and clear "trouble 8"
(all 3 codes)
Key [
MEM
] flashes. Enter two digits (00 to 23) for hours, followed by 2 digits (00 to 59) for minutes.
[
BYP
]
Test report
(all 3 codes)
Reporting is enabled at address 086 keys [11], [12]. A value must be entered at address 512,
and both telephone and account numbers must be programmed.
[
TRBL
]
Call Espload via telephone
(all 3 codes)
Panel identifier, PC password (addresses 004-007) and computer telephone number (addresses
008-015) must be programmed.
[
AWAY
]
Answer Espload
(all 3 codes)
This feature is available when using the ADP-1 adapter. In Espload, "blind dial" must be activated in
"modem setup" section, and panel phone number must be programmed (works also without ADP-1).
[
STAY
]
Cancel communication attempts
(master code and user 1 can only stop calls to Espload)
Until next reportable event
(installer code - all communications)
When communicating with Espload, it is impossible to enter programming mode.
“POWER-DOWN” RESET
(1) Remove battery and AC to power down the unit.
(4) Wait 10 seconds.
(2) Connect a jumper between "reset jumper" pins.
(5) Remove jumper.
(3) Connect AC then battery.
Factory default installer and master codes will be reinstated. Values entered at addresses 008-043, 062-
126, 300-527, as well as all user codes, will be erased ([2
ND
] [2
ND
]). Programmed values of all other
addresses do not change.
Paradox Security Systems - Graphic Dept. - PRINTED IN CANADA
WARRANTY
Warranty conditions for the
ESPRIT may vary from country to country. Please consult your local dealer
for complete warranty information. In all cases, the warranty does not cover malfunctions arising from
installer error or failure to follow installation/operation instructions, nor does it apply to damages due to
causes beyond the control of Paradox Security Systems, such as lightning, excessive voltage, mechani-
cal shock or water damage.
LIABILITY
Under no circumstances shall Paradox Security Systems be held liable for any direct or indirect dam-
ages, loss of anticipated profits, loss of time, or any other losses incurred by the buyer in connection
with the purchase, installation, operation or failure of this product.
WARNING
This security system should undergo frequent testing. However, despite regular testing, and due to, but not
limited to, criminal tampering or electrical disruption, it is possible for this product to fail to perform as expected.
29