Operational note regarding special timing functions
The time programmed at addresses 044 and 045 can be used to:
• Transmit “Late to Close” code, address 516 (SECTION 65), if the system is not armed by a specified time.
• Auto-arm the system and if programmed, transmit the arming code at address 300 (SECTION 11)
after transmitting the “Late to Close” code (as above).
The time programmed at addresses 047 and 048 can be used to:
• Specify the time of day for the Test Report (code programmed at address 512 (SECTION 64).
The amount of time programmed at address 055 (Max = 63.75 hours) can be used to:
• Transmit the “No Movement” code, address 517 (SECTION 65), if there is no movement in the protected
area while the system is disarmed.
• Auto-arm the system and if programmed, transmit the arming code at address 300 (SECTION 11)
after transmitting the No Movement code (as above).
The "Late to Close" code programmed at address 516 (SECTION 65) will be transmitted:
• At the time programmed at addresses 044 and 045 if the system is not armed.
The "No Movement" code programmed at address 517 (SECTION 65) will be transmitted:
• After the time programmed at address 055 expires.
The amount of time programmed at address 056 (Max = 127 minutes) can be used to:
• Designate the length of time a programmable output (PGM) will remain active following a specified event.
Auto test report options
Reports the code programmed at address 512 after the number of days programmed at address 046, at
the time programmed at addresses 047, 048. (To disable, program 000 at address 046.)
Auto arm options
1) Send a "late to close" code programmed at address 516.
2) Auto arm the system (on time) if enabled at address 086, key [5].
3) Auto arm the system (no movement) if enabled at address 086, key [6].
Exit Delay
(Address 049)
Range 001 to 255 seconds (
factory default 060 seconds). Applies to all zones upon arming.
Entry Delay 1
(Address 050)
Range 001 to 255 seconds (
factory default 045 seconds). Applies upon entry to all zones not selected at
addresses 100 to 114.
Entry Delay 2
(Address 051)
Range 001 to 255 seconds (
factory default 045 seconds). Applies to all zones selected at addresses 112,
114, upon entry.
Bell Cut-off Time
(Address 052)
Range 001 to 255 minutes (
factory default 005 minutes).
Zone Speed
(Address 053)
Range 001 to 255 X 15mSec., (
factory default 600 mSec). Maximum time 3.8 seconds.
Power Failure Report Delay
(Address 054)
Range 001 to 255 minutes, (
factory default 030 minutes), (000 = disabled)
. Delay code reported at address 499.
"No Movement" report time
(Address 055)
Range 001 to 255 X 15 minutes. (
Factory default 8 hours (000 = disabled)). System will automatically
arm after programmed number of minutes of inactivity if enabled at address 086, key [6], or will transmit
code programmed at address 517. (Maximum time 63.75 hours)
16
IM738-738EX